Doppler ultrasonographic, oscillometric sphygmomanometric, and photoplethysmographic techniques for noninvasive blood pressure measurement in anesthetized cats.

S H Binns1, D D Sisson, D A Buoscio, D J Schaeffer.   

Abstract

Blood pressure (BP) measurements obtained using 3 indirect BP measuring instruments, a Doppler ultrasonic flowmeter, an oscillometric device, and a photoplethysmograph, were compared with direct arterial pressure measurements in 11 anesthetized cats. The standard deviation of the differences (SDD) between direct and indirect pressure measurements were not significantly different from each other (P < .01), and ranged from 10.82 to 24.32 mm Hg. The high SDD values indicate that indirect BP estimates obtained with all these devices must be interpreted cautiously in individual patients. The mean errors (calculated as the sum of the differences between direct and indirect pressure measurements divided by the number of observations) of the 3 indirect devices were significantly different for systolic (SAP), diastolic (DAP), and mean (MAP) arterial pressures (P < .05). The Doppler and photoplethysmographic devices had the highest overall accuracy, as indicated by mean error values of less than 10 mm Hg. Correlation coefficients varied from .88 to .96 for the Doppler flowmeter, and from .85 to .94 for the photoplethysmograph; for both devices, the regression line slopes were close to unity. The Doppler flowmeter detected a pulse under all experimental conditions. The photoplethysmograph was also efficient in obtaining BP measurements, obtaining over 90% of SAP, DAP, and MAP readings attempted. The oscillometric device was the least accurate, with mean error values varying from 10 to 22 mm Hg. Correlation coefficients were high (.90 to .94) for this device, but the slopes of the regression lines were 0.7 to 0.8, indicating a trend for increased error at higher BP. The oscillometric device tended to underestimate BP by increasing amounts as the BP increased. The oscillometric device was the least efficient device for obtaining BP measurements (P < .01).

Entities:  

Mesh:

Year:  1995        PMID: 8558488     DOI: 10.1111/j.1939-1676.1995.tb03301.x

Source DB:  PubMed          Journal:  J Vet Intern Med        ISSN: 0891-6640            Impact factor:   3.333


  13 in total

1.  Comparison of invasive and non-invasive blood pressure monitoring during clinical anaesthesia in dogs.

Authors:  Paul D MacFarlane; Nicola Grint; Alexandra Dugdale
Journal:  Vet Res Commun       Date:  2010-03-23       Impact factor: 2.459

2.  Comparison of Direct and Indirect Methods of Measuring Arterial Blood Pressure in Healthy Male Rhesus Macaques (Macaca mulatta).

Authors:  Logan K France; Meghan S Vermillion; Caroline M Garrett
Journal:  J Am Assoc Lab Anim Sci       Date:  2018-01-01       Impact factor: 1.232

Review 3.  Basics of monitoring equipment.

Authors:  Tanya Duke-Novakovski
Journal:  Can Vet J       Date:  2017-11       Impact factor: 1.008

4.  Constant-Rate Infusion of Dexmedetomidine to Manage Thiopental Anesthesia during Intracranial Surgery in Cynomolgus Macaques (Macaca fascicularis).

Authors:  Noemi Romagnoli; Alessandra Buonacucina; Carlotta Lambertini; Domenico Ventrella; Angelo Peli
Journal:  J Am Assoc Lab Anim Sci       Date:  2016-11       Impact factor: 1.232

5.  Tissue motion annular displacement to assess the left ventricular systolic function in healthy cats.

Authors:  Giovana Lais Ruviaro Tuleski; Marcela Wolf; Maria Jose Garcia Ribeiro Pscheidt; Júlio Pereira Dos Santos; Marlos Gonçalves Sousa
Journal:  Vet Res Commun       Date:  2022-03-08       Impact factor: 2.816

6.  Accuracy and Precision of Noninvasive Blood Pressure in Normo-, Hyper-, and Hypotensive Standing and Anesthetized Adult Horses.

Authors:  N Heliczer; O Lorello; D Casoni; C Navas de Solis
Journal:  J Vet Intern Med       Date:  2016-04-05       Impact factor: 3.333

7.  Blood Pressure Measurements in 780 Apparently Healthy Cats.

Authors:  J R Payne; D C Brodbelt; V Luis Fuentes
Journal:  J Vet Intern Med       Date:  2016-12-01       Impact factor: 3.333

8.  Relationship between indirect blood pressure and various stages of chronic kidney disease in cats.

Authors:  Yasutomo Hori; Yasuhiro Heishima; Yohei Yamashita; Noriko Isayama; Nobuyuki Kanno; Kensuke Nakamura; Masayuki Iguchi; Toshiki Ibaragi; Hideyuki Onodera; Yoshitaka Aramaki; Atsushi Hirakawa; Shigeki Yamano; Michio Katagi; Akihito Kitade; Tamotsu Sawada
Journal:  J Vet Med Sci       Date:  2018-01-03       Impact factor: 1.267

9.  Indirect arterial blood pressure measurement in healthy anesthetized cats using a device that combines oscillometry with photoplethysmography.

Authors:  Yasuhiro Heishima; Yasutomo Hori; Seishiro Chikazawa; Kazutaka Kanai; Fumio Hoshi; Naoyuki Itoh
Journal:  J Vet Med Sci       Date:  2016-03-18       Impact factor: 1.267

10.  ACVIM consensus statement: Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats.

Authors:  Mark J Acierno; Scott Brown; Amanda E Coleman; Rosanne E Jepson; Mark Papich; Rebecca L Stepien; Harriet M Syme
Journal:  J Vet Intern Med       Date:  2018-10-24       Impact factor: 3.333

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.