Literature DB >> 8556951

Standardization of absolute CD4+ lymphocyte counts across laboratories: an evaluation of the Ortho CytoronAbsolute flow cytometry system on normal donors.

M C Connelly1, M Knight, J V Giorgi, J Kagan, A L Landay, J W Parker, E Page, C Spino, C Wilkening, T J Mercolino.   

Abstract

The Ortho CytoronAbsolute is a flow cytometer designed to provide direct absolute counts of lymphocytes and their subsets from a single instrument. This study was designed to determine the performance of four geographically separated CytoronAbsolute instruments using 24-h-old, shipped, whole blood samples and to compare the results obtained on the CytoronAbsolute to those obtained using combinations of hematology instruments and other flow cytometers. The absolute count feature of the CytoronAbsolutes located at the four sites were cross calibrated and gave across-site coefficients of variation (CVs) of <4.0% for absolute count and 8.2% for absolute lymphocyte count. The calibration was stable for at least 2 months. Absolute lymphocyte counts and lymphocyte percentage immunophenotypes were determined on blood from 50 healthy human immunodeficiency virus (HIV)-seronegative donors. There were no significant site-to-site differences (each P > .05) in CD3+/CD4+ absolute lymphocyte counts determined on the CytoronAbsolute. In contrast, there was a significant site-to-site difference (P < .001) between sites 2 and 3 and sites 3 and 4 in the absolute CD3+/CD4+ lymphocyte counts determined via the conventional method of combining a flow cytometry-derived percentage with a hematology instrument-derived lymphocyte count. There was no significant difference (P = .388) in CD3+/CD4+ lymphocyte percent determinations between the CytoronAbsolute and the FACScan or Profile II flow cytometers used in this study. These results demonstrate that different operators can cross calibrate CytoronAbsolutes for absolute CD3+/CD4+ lymphocyte subset determinations, even over large geographic distances.

Entities:  

Mesh:

Year:  1995        PMID: 8556951     DOI: 10.1002/cyto.990220307

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  7 in total

1.  Multisite comparison of CD4 and CD8 T-lymphocyte counting by single- versus multiple-platform methodologies: evaluation of Beckman Coulter flow-count fluorospheres and the tetraONE system. The NIAID DAIDS New Technologies Evaluation Group.

Authors:  K A Reimann; M R O'Gorman; J Spritzler; C L Wilkening; D E Sabath; K Helm; D E Campbell
Journal:  Clin Diagn Lab Immunol       Date:  2000-05

2.  Affordable CD4(+)-T-cell counting by flow cytometry: CD45 gating for volumetric analysis.

Authors:  George Janossy; Ilesh V Jani; Nicholas J Bradley; Arsene Bikoue; Tim Pitfield; Debbie K Glencross
Journal:  Clin Diagn Lab Immunol       Date:  2002-09

3.  Evaluation of a new single-parameter volumetric flow cytometer (CyFlow(green)) for enumeration of absolute CD4+ T lymphocytes in human immunodeficiency virus type 1-infected Thai patients.

Authors:  Kovit Pattanapanyasat; Surada Lerdwana; Egarit Noulsri; Thanyanan Chaowanachan; Punneeporn Wasinrapee; Natthaga Sakulploy; Vallerut Pobkeeree; Orapin Suksripanich; Sombat Thanprasertsuk; Thomas J Spira; Jordan W Tappero; William C Levine
Journal:  Clin Diagn Lab Immunol       Date:  2005-12

4.  Absolute CD4 counts obtained by a three-color flow-cytometric method without the use of a hematology analyzer.

Authors:  T S Alexander
Journal:  Clin Diagn Lab Immunol       Date:  1998-03

5.  Inter- and intrainstitutional evaluation of automated volumetric capillary cytometry for the quantitation of CD4- and CD8-positive T lymphocytes in the peripheral blood of persons infected with human immunodeficiency virus. Site Investigators and the NIAID New CD4 Technologies Focus Group.

Authors:  M R O'Gorman; R Gelman
Journal:  Clin Diagn Lab Immunol       Date:  1997-03

6.  Low CD4+ T-lymphocyte values in human immunodeficiency virus-negative adults in Botswana.

Authors:  Hermann Bussmann; C William Wester; Kereng V Masupu; Trevor Peter; Sarah M Gaolekwe; Soyeon Kim; Ann Marie Reich; Sam Ahn; Ying Wu; Ibou Thior; Max Essex; Richard Marlink
Journal:  Clin Diagn Lab Immunol       Date:  2004-09

7.  A randomised trial of subcutaneous intermittent interleukin-2 without antiretroviral therapy in HIV-infected patients: the UK-Vanguard Study.

Authors:  Mike Youle; Sean Emery; Martin Fisher; Mark Nelson; Lisa Fosdick; George Janossy; Clive Loveday; Ann Sullivan; Christian Herzmann; Handan Wand; Richard T Davey; Margaret A Johnson; Jorge A Tavel; H Clifford Lane
Journal:  PLoS Clin Trials       Date:  2006-05-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.