Wear of the polyethylene acetabular cup. The effect of head material, head diameter, and cup thickness studied with a hip simulator.

V O Saikko1.   

Abstract

Ultra-high molecular weight polyethylene acetabular cups backed by Ti-6Al-4V acetabular shells were articulated against Co-Cr-Mo alloy, ion-implanted Co-Cr-Mo alloy, and zirconia ceramic femoral heads in a hip joint simulator. Three tests of three million walking cycles each were run with five different head-cup combinations. The wear of the cups was measured gravimetrically at half a million cycle intervals. When the thickness of the cup was 10.9 mm, the mean wear rate was 0.14 mm/year against 28 mm dia. Co-Cr-Mo heads and 0.09 mm/year against ion-implanted 28 mm Co-Cr-Mo heads. When the thickness of the cup was 7.0 mm, the mean wear rate was 0.04 mm/year against 28 mm zirconia heads, but when the thickness was 10.9 mm, no wear occurred against 28 and 32 mm zirconia heads. The results indicate that a significant reduction in the wear of the polyethylene cup can be expected if zirconia is used as the head material, instead of Co-Cr-Mo alloy or ion-implanted Co-Cr-Mo alloy. The diameter of the zirconia head, 28 vs. 32 mm, seems unimportant, but a cup thickness much below 10 mm may be disadvantageous.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8553815     DOI: 10.3109/17453679509002302

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  8 in total

1.  Increased volumetric wear of polyethylene liners with more than 3 years of shelf-life time.

Authors:  T J S Puolakka; J T Keränen; K A Juhola; K J J Pajamäki; P J Halonen; J K Nevalainen; V Saikko; M U K Lehto; M Järvinen
Journal:  Int Orthop       Date:  2003-04-01       Impact factor: 3.075

2.  The effects of polyethylene cup thickness on wear of total hip prostheses.

Authors:  H Oonishi; H Iwaki; N Kin; S Kushitani; N Murata; S Wakitani; K Imoto
Journal:  J Mater Sci Mater Med       Date:  1998-08       Impact factor: 3.896

3.  [Total hip replacement in developmental dysplasia: anatomical features and technical pitfalls].

Authors:  B M Holzapfel; D Bürklein; F Greimel; U Nöth; M Hoberg; H Gollwitzer; M Rudert
Journal:  Orthopade       Date:  2011-06       Impact factor: 1.087

4.  Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.

Authors:  Marcel E Roy; Leo A Whiteside; Mark E Magill; Brian J Katerberg
Journal:  Clin Orthop Relat Res       Date:  2011-02-11       Impact factor: 4.176

5.  Effect of Operation Room Nursing Intervention and Ceramic Prosthesis on Total Hip Arthroplasty.

Authors:  Ting Xu; Jie Zhang
Journal:  Scanning       Date:  2022-06-21       Impact factor: 1.750

6.  The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups--finite element simulations and experimental tests.

Authors:  Rami K Korhonen; Arto Koistinen; Yrjö T Konttinen; Seppo S Santavirta; Reijo Lappalainen
Journal:  Biomed Eng Online       Date:  2005-05-17       Impact factor: 2.819

7.  Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings.

Authors:  Murat Ali; Mazen Al-Hajjar; Susan Partridge; Sophie Williams; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2016-05       Impact factor: 1.617

8.  Catastrophic wear in uncemented acetabular cups after Total Hip Arthroplasty. A case series.

Authors:  Salomon Jasqui Remba; Ricardo Esquivel Gomez; Luis Gutiérrez Ambriz; Daniel Portman Santos; Isaac Baley Amiga
Journal:  Int J Surg Case Rep       Date:  2021-03-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.