Literature DB >> 8551995

Calculation of dose distributions in the vicinity of high-Z interfaces for photon beams.

O A Sauer1.   

Abstract

In the vicinity of interfaces between materials of different atomic number Z, extremes in absorbed dose occur for high-energy photon irradiations. The spatial extension of the effects is within the range of 1 cm, which may not be ignorable from the radiobiological point of view. At the front side of a high-Z slab a maximum is observed, whereas at the exit side a small buildup zone of the dose occurs, e.g., for a 5 MV beam, in front of a water/iron interface, the enhancement is about 30% of that to the homogeneous medium. The reduction at the back of the iron slab is about 16% for this energy, but vanishes with increasing energy. For high-energy photons this effect is mainly caused by the strong atomic number dependence of the scattering power for secondary electrons. The amount and extent of the scattering effects have been measured for aluminum and for iron slabs embedded in water or PMMA. The experimental data are in good agreement with Monte Carlo calculated values. Therefore the data form a reliable base to test the performance of commonly used treatment planning algorithms. The convolution or superposition method is used to calculate dose distributions. To account for the Z dependence of the scattering and the stopping power of the secondary electrons, corrections are applied to the energy deposition kernels. The boundary crossing of energy deposition kernels can be treated only in an approximate manner. However, the algorithm developed improves the accuracy of the dose calculation in the vicinity of interfaces significantly.

Entities:  

Mesh:

Year:  1995        PMID: 8551995     DOI: 10.1118/1.597433

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Linear attenuation coefficient and buildup factor of MCP-96 alloy for dose accuracy, beam collimation, and radiation protection.

Authors:  Deidre N Hopkins; Muhammad Maqbool; Mohammed S Islam
Journal:  Radiol Phys Technol       Date:  2012-05-15

2.  Evaluation of the radiotherapy treatment planning in the presence of a magnetic valve tissue expander.

Authors:  Débora M Trombetta; Simone C Cardoso; Victor G L Alves; Alessandro Facure; Delano V S Batista; Ademir X da Silva
Journal:  PLoS One       Date:  2015-02-13       Impact factor: 3.240

3.  Study of dosimetric properties of flattened and unflattened megavoltage x ray beam on high Z implant materials.

Authors:  Tamilarasan Rajamanickam; Sivakumar Muthu; Perumal Murugan; Muddappa Pathokonda; Krishnamoorthy Senthilnathan; Narayanasamy Arunai Nambi Raj; Padmanabhan Ramesh Babu
Journal:  J Appl Clin Med Phys       Date:  2018-09-28       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.