Design of compensators for breast radiotherapy using electronic portal imaging.

P M Evans1, V N Hansen, W P Mayles, W Swindell, M Torr, J R Yarnold.   

Abstract

A novel method of designing intensity modulated beams (IMBs) to achieve compensation in external beam radiotherapy of the breast, without the need for CT scans, is presented. The design method comprises three parts: (1) an electronic portal image is used to generate a map of radiological thickness; (2) this map is then used to obtain an estimate of the breast and lung outline; (3) a TMR-based dose calculation algorithm is then used to determine the optimum beam profile to achieve the best dose distribution. The dose distributions calculated for IMBs were compared with those calculated for the use of simple wedges. The results for two patients studied indicate that the dose inhomogeneity for IMBs is +/- 5%, compared with a value of +/- 10% for a wedged plan. The uncertainty in radiological thickness measurement corresponds to a dosimetric error of +/- 2%. Other errors associated with outline estimation are typically less than 2%, with a largest value of +5% for one of the patients who had a large and highly asymmetrical breast. The results for the two patients studied suggest that the uncertainties in the method are significantly smaller than the improvement in dose uniformity produced.

Entities:  

Mesh:

Year:  1995        PMID: 8539456     DOI: 10.1016/0167-8140(95)01617-p

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  4 in total

1.  A dual two dimensional electronic portal imaging device transit dosimetry model based on an empirical quadratic formalism.

Authors:  Y I Tan; M Metwaly; M Glegg; S P Baggarley; A Elliott
Journal:  Br J Radiol       Date:  2015-05-13       Impact factor: 3.039

2.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

3.  Assessment of the accuracy of dose calculation in the build-up region of the tangential field of the breast for a radiotherapy treatment planning system.

Authors:  Bagher Farhood; Mohammad Taghi Bahreyni Toossi; Shokouhozaman Soleymanifard; Tohid Mortezazadeh
Journal:  Contemp Oncol (Pozn)       Date:  2017-09-29

4.  The effect of respiratory motion on electronic portal imaging device dosimetry.

Authors:  Andrew L Fielding; Jessica Benitez Mendieta; Sarah Maxwell; Catherine Jones
Journal:  J Appl Clin Med Phys       Date:  2019-02-05       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.