Literature DB >> 8535879

Nellcor Stat Cap differentiates oesophageal from tracheal intubation.

P D Sutherland1, M Quinn.   

Abstract

A trial of the Nellcor Stat Cap, which detects exhaled carbon dioxide, as an aid to determining whether endotracheal tubes are placed in the oesophagus or the trachea, was carried out in the neonatal unit of this hospital. Twenty five neonates, with a mean (range) gestational age of 33 (24-42) weeks and a mean (range) birthweight of 2.17 (0.54-4.1) kg were studied over two months. These babies underwent a total of 58 intubations and 20 suspected self-extubations. The Nellcor Stat Cap was easy to use. It confirmed clinical findings on 20/20 occasions when the endotracheal tube was in the oesophagus and on 57/58 (98%) occasions when it was in the trachea. On 14/78 (19%) occasions the machine provided helpful additional information in reaching a decision on the adequacy of tube placement. Failure to detect rapidly accidental oesophageal intubation or unintentional tracheal extubation can result in rapid deterioration of the condition of ventilated newborns. The machine is a valuable aid to intubation and rapid diagnosis of self-extubation.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8535879      PMCID: PMC2528483          DOI: 10.1136/fn.73.3.f184

Source DB:  PubMed          Journal:  Arch Dis Child Fetal Neonatal Ed        ISSN: 1359-2998            Impact factor:   5.747


  13 in total

1.  Tracheal intubation is not invariably confirmed by capnography.

Authors:  S M Dunn; P S Mushlin; L J Lind; D Raemer
Journal:  Anesthesiology       Date:  1990-12       Impact factor: 7.892

2.  Auscultation cannot distinguish esophageal from tracheal passage of tube.

Authors:  A R Mizutani; G Ozaki; J L Benumof; M S Scheller
Journal:  J Clin Monit       Date:  1991-07

Review 3.  Esophageal intubation: a review of detection techniques.

Authors:  P K Birmingham; F W Cheney; R J Ward
Journal:  Anesth Analg       Date:  1986-08       Impact factor: 5.108

4.  Unusual cause of an absent capnogram.

Authors:  B P Markovitz; M Silverberg; R I Godinez
Journal:  Anesthesiology       Date:  1989-12       Impact factor: 7.892

5.  The Australian Incident Monitoring Study. Oesophageal intubation: an analysis of 2000 incident reports.

Authors:  R Holland; R K Webb; W B Runciman
Journal:  Anaesth Intensive Care       Date:  1993-10       Impact factor: 1.669

6.  The capnogram as a guide to the efficacy of cardiac massage.

Authors:  Z Kalenda
Journal:  Resuscitation       Date:  1978       Impact factor: 5.262

7.  Early detection of endotracheal tube accidents by monitoring carbon dioxide concentration in respiratory gas.

Authors:  I P Murray; J H Modell
Journal:  Anesthesiology       Date:  1983-10       Impact factor: 7.892

8.  Signs of endotracheal intubation.

Authors:  T H Howells; R J Riethmuller
Journal:  Anaesthesia       Date:  1980-10       Impact factor: 6.955

9.  Accidental intubation of the oesophagus.

Authors:  B J Pollard; F Junius
Journal:  Anaesth Intensive Care       Date:  1980-05       Impact factor: 1.669

10.  Capnography for detection of accidental oesophageal intubation.

Authors:  K Linko; M Paloheimo; T Tammisto
Journal:  Acta Anaesthesiol Scand       Date:  1983-06       Impact factor: 2.105

View more
  1 in total

Review 1.  Question 2. Should carbon dioxide detectors be used to check correct placement of endotracheal tubes in preterm and term neonates?

Authors:  Harsha Gowda
Journal:  Arch Dis Child       Date:  2011-12       Impact factor: 3.791

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.