Literature DB >> 852947

Hemodynamic changes distal to selective arterial injections.

D C Levin, D A Phillips, S Lee-Son, P R Maroko.   

Abstract

It has been assumed previously that the act of selectively injecting fluid through a catheter into an artery does not significantly alter hemodynamics in that vessel, provided open communication is maintained between the distal portion of the artery and the aortic lumen. In this study, blood flow was measured with an electromagnetic flow probe in distal branches of the left coronary or superior mesenteric arteries of 9 dogs while heparinized arterial blood was injected selectively into the parent vessels at varying rates up to 7 ml/sec. This resulted, in all experiments, in an abrupt and substantial rise in blood flow which was maintained for the duration of the injection. This phenomeon is due primarily to an increase in intraarterial pressure distal to the catheter tip, caused by the injection.

Entities:  

Mesh:

Year:  1977        PMID: 852947     DOI: 10.1097/00004424-197703000-00003

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  8 in total

1.  The mixability of angiographic contrast with arterial blood.

Authors:  Baruch B Lieber; Chander Sadasivan; Qing Hao; Jaehoon Seong; Liliana Cesar
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

2.  A variation in the origin of the posterior descending coronary artery.

Authors:  D A Phillips; J Berman
Journal:  Cardiovasc Intervent Radiol       Date:  1984       Impact factor: 2.740

3.  Doppler-sonographic examination of the arterial flow in the carotid and supratrochlear arteries during carotid angiography.

Authors:  P Stoeter; N Prey; C Hoffmann; H J Büdingen; R Bergleiter
Journal:  Neuroradiology       Date:  1984       Impact factor: 2.804

4.  Hemodynamic effects of rapid injection into the canine superior mesenteric artery.

Authors:  E D Jacobson; C Eldon; J D Fondacaro
Journal:  Dig Dis Sci       Date:  1981-10       Impact factor: 3.199

5.  Effects of a rapid injection into the canine superior mesenteric artery of diatrizoate meglumine and diatrizoate sodium (Renografin-76).

Authors:  E D Jacobson; C Eldon; J D Fondacaro
Journal:  Cardiovasc Intervent Radiol       Date:  1980       Impact factor: 2.740

6.  Thrombin activatable fibrinolysis inhibitor : its role in slow coronary flow.

Authors:  M N Yildirim; Y Selcoki; S Uysal; A B Nacar; B Demircelik; H I Aydin; B Eryonucu
Journal:  Herz       Date:  2013-09-27       Impact factor: 1.443

7.  An in vitro study of pressure increases during contrast injections in diagnostic cerebral angiography.

Authors:  Samantha Marfoglio; Brandon Kovarovic; Wei Hou; David J Fiorella; Chander Sadasivan
Journal:  Interv Neuroradiol       Date:  2021-02-25       Impact factor: 1.764

8.  Effect of saline injection mixing on accuracy of conductance lumen sizing of peripheral vessels.

Authors:  Hyo Won Choi; Benjamin Jansen; David Birrer; Ghassan S Kassab
Journal:  PLoS One       Date:  2013-09-13       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.