Literature DB >> 8526291

Reliability of the Bolton tooth-size analysis when applied to crowded dentitions.

W C Shellhart1, D W Lange, G T Kluemper, E P Hicks, A L Kaplan.   

Abstract

The Bolton tooth-size analysis is widely taught and used in orthodontics. However, its reliability has not been documented. The purpose of this study was to evaluate the reliability of the analysis when performed with needle-pointed dividers and a Boley gauge. Four clinicians measured the teeth on 15 sets of casts with two instruments at two sessions. The measurements were used to calculate tooth-size excess. To evaluate the measurement error, the difference between the two analyses made by the same investigator on the same set of casts was calculated. More of the same-investigator analyses were significantly correlated when the Boley gauge was used than when the needle-pointed dividers were used. Between-investigator analyses revealed significant correlations for each measurement session with both instruments. Every investigator was found to have at least one measurement error for each analysis and with each instrument that was as large as a clinically significant result of a Bolton analysis. The results of this study demonstrate that clinically significant measurement errors can occur when the Bolton tooth-size analysis is performed on casts with at least 3 mm of crowding. The Boley gauge demonstrated a higher frequency of significantly correlated repeated measures and thus may be somewhat more reliable for this analysis than the needle-pointed dividers.

Mesh:

Year:  1995        PMID: 8526291     DOI: 10.1043/0003-3219(1995)065<0327:ROTBTA>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  8 in total

1.  The tooth-width relation of the incisors in closed bite.

Authors:  G Schuster
Journal:  J Orofac Orthop       Date:  1999       Impact factor: 1.938

2.  A clinical analysis of tooth size discrepancy (Bolton index) among orthodontic patients in Wuhan of Central China.

Authors:  Philipos Tadesse; Handong Zhang; Xiaosi Long; Lili Chen
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2008-08-15

3.  Reliability of Bolton analysis evaluation in tridimensional virtual models.

Authors:  Marianna Mendonca Brandão; Marcio Costal Sobral; Carlos Jorge Vogel
Journal:  Dental Press J Orthod       Date:  2015-10

4.  Digital model as an alternative to plaster model in assessment of space analysis.

Authors:  A Anand Kumar; Abraham Phillip; Sathesh Kumar; Anuradha Rawat; Sakthi Priya; V Kumaran
Journal:  J Pharm Bioallied Sci       Date:  2015-08

5.  Assessment of crown angulations, crown inclinations, and tooth size discrepancies in a South Indian population.

Authors:  Geeta Maruti Doodamani; Anmol S Khala; Mala Manohar
Journal:  Contemp Clin Dent       Date:  2011-07

6.  Accuracy of Bolton analysis measured in laser scanned digital models compared with plaster models (gold standard) and cone-beam computer tomography images.

Authors:  Jooseong Kim; Manuel O Lagravére
Journal:  Korean J Orthod       Date:  2016-01-25       Impact factor: 1.372

7.  Comparison of Bolton analysis and tooth size measurements obtained using conventional and three-dimensional orthodontic models.

Authors:  Ruhi Nalcaci; Tolga Topcuoglu; Firat Ozturk
Journal:  Eur J Dent       Date:  2013-09

8.  Investigation of the effects of storage time on the dimensional accuracy of impression materials using cone beam computed tomography.

Authors:  Murat Alkurt; Zeynep Yeşıl Duymus; Numan Dedeoglu
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.