Literature DB >> 8525560

A survey of the acoustic outputs of diagnostic ultrasound equipment in current clinical use.

J Henderson1, K Willson, J R Jago, T A Whittingham.   

Abstract

Surveys published up to 1991 have highlighted a steady increase in the acoustic outputs from diagnostic ultrasound equipment. Since 1991 we have made measurements of the maximum peak negative pressure (p-) and spatial peak temporal average intensity (ISPTA) produced by 223 probes from 82 scanning systems in current clinical use in the Northern Region in the UK. Measurements have also been made of the maximum total acoustic power generated by 45 probes from 17 scanners. The results from these measurements are presented in this article and compared to the results of a similar survey of equipment from both the Northern and Wessex Regions in the UK and published in 1991. The comparison shows that measured ISPTA values have increased approximately sixfold in B mode and approximately threefold in colour Doppler mode. Also, measured total acoustic power values have doubled in pulsed Doppler mode. The present survey also draws attention to some particularly high ISPTA values obtained from a number of probes and scanning systems. This survey has shown that measurements of acoustic outputs from diagnostic ultrasound scanners in current clinical use are substantially higher than reported in earlier surveys and, for certain scanners, the acoustic outputs from scanned beam modes of operation can reach levels hitherto only found in pulsed Doppler mode.

Mesh:

Year:  1995        PMID: 8525560     DOI: 10.1016/0301-5629(94)00158-a

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Ultrasonic imaging: safety considerations.

Authors:  Gail Ter Haar
Journal:  Interface Focus       Date:  2011-05-25       Impact factor: 3.906

2.  Survey of current practice in clinical transvaginal ultrasound scanning in the UK.

Authors:  Eleanor Martin; Adam Shaw; Christoph Lees
Journal:  Ultrasound       Date:  2015-04-28

3.  Ultrasound transducer and system for real-time simultaneous therapy and diagnosis for noninvasive surgery of prostate tissue.

Authors:  Jong Seob Jeong; Jin Ho Chang; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-09       Impact factor: 2.725

4.  Prenatal ultrasound and the risk of childhood brain tumour and its subtypes.

Authors:  K Stålberg; B Haglund; O Axelsson; S Cnattingius; S Pfeifer; H Kieler
Journal:  Br J Cancer       Date:  2008-03-18       Impact factor: 7.640

5.  Measurement of Thermal Effects of Doppler Ultrasound: An In Vitro Study.

Authors:  Samir Helmy; Yvonne Bader; Marianne Koch; Denise Tiringer; Christian Kollmann
Journal:  PLoS One       Date:  2015-08-24       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.