Literature DB >> 8524032

Blood oxygenation dependence of T1 and T2 in the isolated, perfused rabbit heart at 4.7T.

M K Atalay1, S B Reeder, E A Zerhouni, J R Forder.   

Abstract

An MR line scan protocol has been used to measure relaxation parameters (T1 and T2) in isolated, blood perfused rabbit hearts at various blood oxygenations. Hearts were retrogradely perfused at 37 degrees C with a cardioplegic solution (modified St. Thomas' solution) containing sheep red blood cells and adenosine (1 mM) to maximally vasodilate the coronary vascular bed. Arresting the hearts eliminated motion complications and minimized arteriovenous oxygenation differences. The authors have found that under conditions of stable flow, there is a strong correlation between T2 in myocardial septa and hemoglobin (Hb) saturation, while tissue T1 is virtually independent of blood oxygenation. These effects are believed to be due to the paramagnetic agent deoxyhemoglobin.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8524032     DOI: 10.1002/mrm.1910340420

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  Reconstruction of cardiac ventricular geometry and fiber orientation using magnetic resonance imaging.

Authors:  D F Scollan; A Holmes; J Zhang; R L Winslow
Journal:  Ann Biomed Eng       Date:  2000-08       Impact factor: 3.934

2.  Blood longitudinal (T1) and transverse (T2) relaxation time constants at 11.7 Tesla.

Authors:  Ai-Ling Lin; Qin Qin; Xia Zhao; Timothy Q Duong
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

3.  Detection of scarred and viable myocardium using a new magnetic resonance imaging technique: blood oxygen level dependent (BOLD) MRI.

Authors:  M Egred; A Al-Mohammad; G D Waiter; T W Redpath; S K Semple; M Norton; A Welch; S Walton
Journal:  Heart       Date:  2003-07       Impact factor: 5.994

4.  Self-gated PROPELLER-encoded cine cardiac imaging.

Authors:  Chi-Chung Wang; Teng-Yi Huang
Journal:  Int J Cardiovasc Imaging       Date:  2011-11-01       Impact factor: 2.357

5.  Fast measurement of blood T1 in the human carotid artery at 3T: Accuracy, precision, and reproducibility.

Authors:  Wenbo Li; Peiying Liu; Hanzhang Lu; John J Strouse; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2016-07-20       Impact factor: 4.668

Review 6.  Three-dimensional contrast-enhanced and non-contrast-enhanced cardiac magnetic resonance imaging for the assessment of myocardial ischemic reactions: the practice of looking deeply into the myocardium.

Authors:  Cosima Jahnke; Sebastian Kozerke; Bernhard Schnackenburg; Nikolaus Marx; Ingo Paetsch
Journal:  J Nucl Cardiol       Date:  2011-10       Impact factor: 5.952

7.  Quantitative cardiac perfusion: a noninvasive spin-labeling method that exploits coronary vessel geometry.

Authors:  S B Reeder; M K Atalay; E R McVeigh; E A Zerhouni; J R Forder
Journal:  Radiology       Date:  1996-07       Impact factor: 11.105

8.  Assessment of myocardial oxygenation with MRI.

Authors:  Jie Zheng
Journal:  Quant Imaging Med Surg       Date:  2013-04

9.  BOLD-MRI in ten patients with coronary artery disease: evidence for imaging of capillary recruitment in myocardium supplied by the stenotic artery.

Authors:  C M Wacker; M Bock; A W Hartlep; W R Bauer; G van Kaick; S Pfleger; G Ertl; L R Schad
Journal:  MAGMA       Date:  1999-03       Impact factor: 2.310

10.  Quantitative theory for the longitudinal relaxation time of blood water.

Authors:  Wenbo Li; Ksenija Grgac; Alan Huang; Nirbhay Yadav; Qin Qin; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2015-08-18       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.