Literature DB >> 8523604

Determination of sixty percent or greater carotid artery stenosis by duplex Doppler ultrasonography.

J P Carpenter1, F J Lexa, J T Davis.   

Abstract

PURPOSE: The Asymptomatic Carotid Atherosclerosis Study, demonstrating the benefit of carotid endarterectomy for symptom-free patients with 60% or greater carotid artery stenosis, has given rise to the need for development of screening parameters for detection of these lesions. Traditional duplex categories (50% to 79%, 80% to 99%) are not applicable. We sought to develop duplex criteria for determination of 60% or greater carotid artery stenosis by comparison with arteriography.
METHODS: The duplex scans and arteriograms of 110 patients (210 carotid arteries), obtained within 1 month of each other, were reviewed by blinded readers. Arteriographic stenosis was determined by the method of the Asymptomatic Carotid Atherosclerosis Study. Duplex measurements of peak systolic velocity (PSV) and end-diastolic velocity (EDV) were recorded, and ratios of velocities in the internal and common carotid arteries (ICA, CCA) were calculated. Sensitivity, specificity, positive and negative predictive values (PPV, NPV), and accuracy were determined, and receiver-operator characteristic curves were generated.
RESULTS: Interobserver agreement for measurement of arteriographic stenosis was "almost perfect" (kappa = 0.86). The criteria determined for detection of 60% or greater stenosis were as follows: PSVICA > 170 cm/sec (sensitivity 98%, specificity 87%, PPV 88%, NPV 98%, accuracy 92%), EDVICA > 40 cm/sec (sensitivity 97%, specificity 52%, PPV 86%, NPV 86%, accuracy 86%), PSVICA/PSVCCA > 2.0 (sensitivity 97%, specificity 73%, PPV 78%, NPV 96%, accuracy 76%), EDVICA/EDVCCA > 2.4 (sensitivity 100%, specificity 80%, PPV 88%, NPV 100%, accuracy 88%). If all of the above criteria were met, 100% accuracy was achieved.
CONCLUSION: It is concluded that 60% or greater carotid artery stenosis can be reliably determined by duplex criteria. The use of receiver-operator characteristic curves allows the individualization of duplex criteria appropriate to specific clinical situations of patient screening for lesions (high sensitivity and NPV) or use as a sole preoperative imaging modality (high PPV). Individual vascular laboratories must validate their own results.

Entities:  

Mesh:

Year:  1995        PMID: 8523604     DOI: 10.1016/s0741-5214(95)70060-9

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  8 in total

1.  Is carotid endarterectomy beneficial for patients with stenosis?

Authors:  S Patel; M F Evans
Journal:  Can Fam Physician       Date:  1999-06       Impact factor: 3.275

2.  Three-dimensional color Doppler sonography in carotid artery stenosis.

Authors:  Robert A Bucek; Markus Reiter; Albert Dirisamer; Markus Haumer; Angelika Fritz; Erich Minar; Johannes Lammer
Journal:  AJNR Am J Neuroradiol       Date:  2003-08       Impact factor: 3.825

3.  Reappraisal of flow velocity ratio in common carotid artery to predict hemodynamic change in carotid stenosis.

Authors:  Masahiro Kamouchi; Kazuhiro Kishikawa; Yasushi Okada; Tooru Inoue; Setsuro Ibayashi; Mitsuo Iida
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

4.  Systematic review of preoperative carotid duplex ultrasound compared with computed tomography carotid angiography for carotid endarterectomy.

Authors:  T Forjoe; M Asad Rahi
Journal:  Ann R Coll Surg Engl       Date:  2019-02-15       Impact factor: 1.891

5.  Combined use of color duplex ultrasonography and B-flow imaging for evaluation of patients with carotid artery stenosis.

Authors:  Muharrem Tola; Mehmet Yurdakul; Turhan Cumhur
Journal:  AJNR Am J Neuroradiol       Date:  2004 Nov-Dec       Impact factor: 3.825

Review 6.  Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments.

Authors:  Nicolle Cassola; Jose Cc Baptista-Silva; Luis Cu Nakano; Carolina Dq Flumignan; Ricardo Sesso; Vladimir Vasconcelos; Nelson Carvas Junior; Ronald Lg Flumignan
Journal:  Cochrane Database Syst Rev       Date:  2022-07-11

7.  Morphological and hemodynamic patterns of carotid stenosis treated by endarterectomy with patch closure versus stenting: a duplex ultrasound study.

Authors:  Marcia Maria Morales; Alexandre Anacleto; Marcello Azem Buchdid; Paulo Ricardo Baggio Simeoni; Sergio Ledesma; Crescêncio Cêntola; João Carlos Anacleto; Marcela Aldrovani; Carlos Eli Piccinato
Journal:  Clinics (Sao Paulo)       Date:  2010       Impact factor: 2.365

8.  Quantitative Blood Flow Measurements in the Common Carotid Artery: A Comparative Study of High-Frame-Rate Ultrasound Vector Flow Imaging, Pulsed Wave Doppler, and Phase Contrast Magnetic Resonance Imaging.

Authors:  Yigang Du; Haiyan Ding; Le He; Billy Y S Yiu; Linsong Deng; Alfred C H Yu; Lei Zhu
Journal:  Diagnostics (Basel)       Date:  2022-03-11
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.