Literature DB >> 8523285

Comparative study of three semiautomated specular microscopes.

M Landesz1, J V Siertsema, G Van Rij.   

Abstract

We compared two clinical video-assisted specular microscopes (Zeiss, noncontact, and the wide-field Keeler Konan sp 3300, contact) with an autofocus microscope (Konan noncon Robo-ca sp 8000, noncontact) with built-in analyzing software by studying the morphometry of the central corneal endothelium of 12 eyes in 12 patients. The mean coefficients of variation of the cell size analysis of three successive images per cornea for the three methods were 3.9%, 4.0%, and 2.2%, respectively. One-way analysis of variance showed a significant difference in the mean cell area measured with the three methods; there was no significant difference in the results of hexagonality (pleomorphism) and coefficient of variation (polymegathism). Although each microscope showed a high reproducibility, we do not recommend using the three interchangeably. The Konan noncon Robo-ca sp 8000 specular microscope provides a rapid morphometric endothelial analysis. The Keeler Konan sp 3300 is better for more detailed studies and photography of the corneal endothelium.

Entities:  

Mesh:

Year:  1995        PMID: 8523285     DOI: 10.1016/s0886-3350(13)80531-7

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  Automated tri-image analysis of stored corneal endothelium.

Authors:  P Gain; G Thuret; L Kodjikian; Y Gavet; P H Turc; C Theillere; S Acquart; J C Le Petit; J Maugery; L Campos
Journal:  Br J Ophthalmol       Date:  2002-07       Impact factor: 4.638

2.  Influencing factors on chronic endothelial cell loss characterised in a homogeneous group of patients.

Authors:  Daniel Böhringer; Thomas Reinhard; Helga Spelsberg; Rainer Sundmacher
Journal:  Br J Ophthalmol       Date:  2002-01       Impact factor: 4.638

3.  A new mounting bracket for donor eye holder.

Authors:  I N Nartey
Journal:  Br J Ophthalmol       Date:  1996-10       Impact factor: 4.638

4.  Results of small incision extracapsular cataract surgery using the anterior chamber maintainer without viscoelastic.

Authors:  M Wright; H Chawla; A Adams
Journal:  Br J Ophthalmol       Date:  1999-01       Impact factor: 4.638

5.  Specular microscopy ancillary study methods for donor endothelial cell density determination of Cornea Donor Study images.

Authors:  Beth Ann Benetz; Robin L Gal; Katrina J Ruedy; Carmella Rice; Roy W Beck; Andrea D Kalajian; Jonathan H Lass
Journal:  Curr Eye Res       Date:  2006-04       Impact factor: 2.424

6.  Corneal endothelial cell density and morphology in Phramongkutklao Hospital.

Authors:  Narumon Sopapornamorn; Manapon Lekskul; Suthee Panichkul
Journal:  Clin Ophthalmol       Date:  2008-03

7.  Corneal endothelial cell density in healthy Caucasian population.

Authors:  Rahmi Duman; Mediha Tok Çevik; Sadık Görkem Çevik; Reşat Duman; İrfan Perente
Journal:  Saudi J Ophthalmol       Date:  2016-11-02

8.  Corneal endothelial cell density and morphology in normal Iranian eyes.

Authors:  Mohammad Nasser Hashemian; Sasan Moghimi; Masood Aghsaie Fard; Mohammad Reza Fallah; Mohammad Reza Mansouri
Journal:  BMC Ophthalmol       Date:  2006-03-06       Impact factor: 2.209

9.  Comparison of corneal endothelial cell measurements by two non-contact specular microscopes.

Authors:  Laura Gasser; Thomas Reinhard; Daniel Böhringer
Journal:  BMC Ophthalmol       Date:  2015-07-29       Impact factor: 2.209

10.  Assessment of central corneal thickness and corneal endothelial morphology using ultrasound pachymetry, non-contact specular microscopy, and Confoscan 4 confocal microscopy.

Authors:  Haya Matuoq Al Farhan; Wafa'a Majed Al Otaibi; Hanouf Mohammed Al Razqan; Alanoud Abdullah Al Harqan
Journal:  BMC Ophthalmol       Date:  2013-11-25       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.