OBJECTIVE: The size of prostatic carcinomas, as determined by estimations of the tumor volume, has a direct correlation with the histologic grade and stage. Therefore, accurate information about tumor volume can play an important role in determining appropriate treatment and establishing a patient's prognosis. Accordingly, we performed a study to assess the accuracy of MR imaging with external-array coils and the fast spin-echo technique for determining tumor volume in patients with prostatic cancer. SUBJECTS AND METHODS: In a prospective study, 20 patients with biopsy-proved prostatic cancer had MR imaging before radical prostatectomy. A 1.5-T system, a prototype external-array coil, and fast spin-echo technique were used to obtain axial T2-weighted (4000/120 [TR/TE]) MR images throughout the prostate and seminal vesicles. Contiguous 5-mm sections were obtained with a 256 x 256 or 256 x 192 matrix, 24-cm field of view, four excitations, and fat suppression. The volumes of cancer obtained with MR imaging and surgical specimens were determined independently. The areas of tumor were determined from individual axial sections by summing and multiplying by the section thickness. RESULTS: Seventeen of the 20 cancers were detected on MR images. A significant correlation between the volume of the tumor as determined with MR imaging and measurements of the specimens was observed (r = .81, p < .001). Four transition zone tumors were detected as zones of rather homogeneous decreased intensity. One important source of error for volumes determined with MR images was a limitation in the histologic specificity of MR imaging for the delineation of cancer; in some cases benign changes or normal prostates were interpreted as cancer. Another limitation was the presence of changes after biopsy that concealed portions of 10 of the 17 tumors visualized. CONCLUSION: The accuracy of the MR technique used was not sufficient for reliable prediction of tumor volume. The lack of specificity of T2-weighted MR imaging for cancer detection and the presence of changes caused by biopsy were major sources of error.
OBJECTIVE: The size of prostatic carcinomas, as determined by estimations of the tumor volume, has a direct correlation with the histologic grade and stage. Therefore, accurate information about tumor volume can play an important role in determining appropriate treatment and establishing a patient's prognosis. Accordingly, we performed a study to assess the accuracy of MR imaging with external-array coils and the fast spin-echo technique for determining tumor volume in patients with prostatic cancer. SUBJECTS AND METHODS: In a prospective study, 20 patients with biopsy-proved prostatic cancer had MR imaging before radical prostatectomy. A 1.5-T system, a prototype external-array coil, and fast spin-echo technique were used to obtain axial T2-weighted (4000/120 [TR/TE]) MR images throughout the prostate and seminal vesicles. Contiguous 5-mm sections were obtained with a 256 x 256 or 256 x 192 matrix, 24-cm field of view, four excitations, and fat suppression. The volumes of cancer obtained with MR imaging and surgical specimens were determined independently. The areas of tumor were determined from individual axial sections by summing and multiplying by the section thickness. RESULTS: Seventeen of the 20 cancers were detected on MR images. A significant correlation between the volume of the tumor as determined with MR imaging and measurements of the specimens was observed (r = .81, p < .001). Four transition zone tumors were detected as zones of rather homogeneous decreased intensity. One important source of error for volumes determined with MR images was a limitation in the histologic specificity of MR imaging for the delineation of cancer; in some cases benign changes or normal prostates were interpreted as cancer. Another limitation was the presence of changes after biopsy that concealed portions of 10 of the 17 tumors visualized. CONCLUSION: The accuracy of the MR technique used was not sufficient for reliable prediction of tumor volume. The lack of specificity of T2-weighted MR imaging for cancer detection and the presence of changes caused by biopsy were major sources of error.
Authors: Young Hwii Ko; Deuk Jae Sung; Sung Gu Kang; Seok Ho Kang; Jeong Gu Lee; Je Jong Kim; Jun Cheon Journal: Asian J Androl Date: 2011-03-07 Impact factor: 3.285
Authors: Berrend G Muller; Jurgen J Fütterer; Rajan T Gupta; Aaron Katz; Alexander Kirkham; John Kurhanewicz; Judd W Moul; Peter A Pinto; Ardeshir R Rastinehad; Cary Robertson; Jean de la Rosette; Rafael Sanchez-Salas; J Stephen Jones; Osamu Ukimura; Sadhna Verma; Hessel Wijkstra; Michael Marberger Journal: BJU Int Date: 2013-11-13 Impact factor: 5.588
Authors: Graham Sommer; Donna Bouley; Harcharan Gill; Bruce Daniel; Kim Butts Pauly; Chris Diederich Journal: Can J Urol Date: 2013-04 Impact factor: 1.344
Authors: Stephan Zangos; Katrin Eichler; Kerstin Engelmann; Mukhtiar Ahmed; Sebastian Dettmer; Christopher Herzog; Wasilios Pegios; A Wetter; Thomas Lehnert; Martin G Mack; Thomas J Vogl Journal: Eur Radiol Date: 2004-09-04 Impact factor: 5.315
Authors: Yousef Mazaheri; Hedvig Hricak; Samson W Fine; Oguz Akin; Amita Shukla-Dave; Nicole M Ishill; Chaya S Moskowitz; Joanna E Grater; Victor E Reuter; Kristen L Zakian; Karim A Touijer; Jason A Koutcher Journal: Radiology Date: 2009-08 Impact factor: 11.105