Literature DB >> 8515007

Measurement of range of motion of the finger after flexor tendon repair in zone II of the hand.

C W Jansen1, M G Watson.   

Abstract

The purpose of this study was to compare classification systems of active range of motion of the finger after flexor tendon surgery in zone II of the hand. Active range of motion of 20 fingers (16 subjects) was classified according to five systems. Agreement between the systems was only fair. Strickland's original system and the Louisville system rated the results most strictly, followed by Strickland's adjusted system. Buck-Gramcko's systems (in centimeters and degrees) rated the results least strictly. Strickland's systems conformed most closely to measurement principles. This article concludes that at this time Strickland's original classification system is preferable for scientific and clinical purposes. However, additional research is needed to evaluate reliability of the measurement, the variability of the scaling factor of 175 degrees, the sensitivity of the measurement, and the validity of the measurement with regard to functional use of the finger and gliding of the repaired tendon.

Mesh:

Year:  1993        PMID: 8515007     DOI: 10.1016/0363-5023(93)90083-f

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  6 in total

1.  Flexor digitorum profundus tendon tension during finger manipulation.

Authors:  Tatsuro Tanaka; Peter C Amadio; Chunfeng Zhao; Mark E Zobitz; Kai-Nan An
Journal:  J Hand Ther       Date:  2005 Jul-Sep       Impact factor: 1.950

2.  Clinical Results of Flexor Tendon Repair in Zone II Using a six Strand Double Loop Technique.

Authors:  Christiana Savvidou; Tsu-Min Tsai
Journal:  J Hand Microsurg       Date:  2014-08-28

3.  Surface treatment of flexor tendon autografts with carbodiimide-derivatized hyaluronic Acid. An in vivo canine model.

Authors:  Chunfeng Zhao; Yu-Long Sun; Peter C Amadio; Toshikazu Tanaka; Anke M Ettema; Kai-Nan An
Journal:  J Bone Joint Surg Am       Date:  2006-10       Impact factor: 5.284

4.  The effects of oblique or transverse partial excision of the A2 pulley on gliding resistance during cyclic motion following zone II flexor digitorum profundus repair in a cadaveric model.

Authors:  Tamami Moriya; Andrew R Thoreson; Chunfeng Zhao; Kai-Nan An; Peter C Amadio
Journal:  J Hand Surg Am       Date:  2012-07-03       Impact factor: 2.230

5.  Compressive properties of cd-HA-gelatin modified intrasynovial tendon allograft in canine model in vivo.

Authors:  Jun Ikeda; Chunfeng Zhao; Qingshan Chen; Andrew R Thoreson; Kai-Nan An; Peter C Amadio
Journal:  J Biomech       Date:  2011-05-06       Impact factor: 2.712

6.  [Functional results of flexor tendon injuries of the hand: about 90 cases].

Authors:  Hassan Boussakri; Mohamad Azarkane; Mohamad Elidrissi; Mohamad Shimi; Abdelhalim Elibrahimi; Abdelmajid Elmrini
Journal:  Pan Afr Med J       Date:  2013-05-01
  6 in total