Literature DB >> 21549380

Compressive properties of cd-HA-gelatin modified intrasynovial tendon allograft in canine model in vivo.

Jun Ikeda1, Chunfeng Zhao, Qingshan Chen, Andrew R Thoreson, Kai-Nan An, Peter C Amadio.   

Abstract

Although we sometimes use the intrasynovial tendon allograft as a donor, the gliding ability of allograft prepared by lyophilization is significantly decreased. The gliding ability of the grafted tendon after tendon reconstruction is very important because the high gliding resistance causes more adhesion and leads to poor clinical results. We recently revealed that tendon surface treatment with a carbodiimide derivatized HA (cd-HA)-gelatin mixture for intrasynovial tendon allograft significantly improved its gliding ability. The purpose of this study was to investigate whether this cd-HA-gelatin treatment affects the tendon mechanical property or not. A total of 40 flexor digitorum profundus (FDP) tendons from canines were evaluated for compressive property by using indentation test. Indentation stiffness was measured for normal tendon, rehydrated tendon after lyophilization, rehydrated tendon after lyophilization that was implanted 6 weeks in vivo, and cd-HA treated rehydrated tendon after lyophilization that was implanted 6 weeks in vivo. The results for all groups showed no significant difference in the tendon compressive properties. The findings of these results demonstrate that cd-HA treatment for intrasynovial tendon allograft is an excellent method to improve the tendon gliding ability after lyophilization without changing the compressive property of donor tendon.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21549380      PMCID: PMC3625931          DOI: 10.1016/j.jbiomech.2010.12.030

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  38 in total

1.  Ultrasound evaluation of flexor tendon lacerations.

Authors:  D H Lee; M L Robbin; R Galliott; V A Graveman
Journal:  J Hand Surg Am       Date:  2000-03       Impact factor: 2.230

2.  Effect of synergistic motion on flexor digitorum profundus tendon excursion.

Authors:  Chunfeng Zhao; Peter C Amadio; Mark E Zobitz; Toshimitsu Momose; Paulus Couvreur; Kai-Nan An
Journal:  Clin Orthop Relat Res       Date:  2002-03       Impact factor: 4.176

3.  Tensile properties of suture methods for repair of partially lacerated human flexor tendon in vitro.

Authors:  M E Zobitz; C Zhao; L Erhard; P C Amadio; K N An
Journal:  J Hand Surg Am       Date:  2001-09       Impact factor: 2.230

4.  Tendon surface modification by chemically modified HA coating after flexor digitorum profundus tendon repair.

Authors:  Chao Yang; Peter C Amadio; Yu-Long Sun; Chunfeng Zhao; Mark E Zobitz; Kai-Nan An
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2004-01-15       Impact factor: 3.368

5.  Effect of gamma irradiation on remodeling process of tendon allograft.

Authors:  Tatsuo Mae; Konsei Shino; Akira Maeda; Yukiyoshi Toritsuka; Shuji Horibe; Takahiro Ochi
Journal:  Clin Orthop Relat Res       Date:  2003-09       Impact factor: 4.176

6.  Tensile properties of canine intrasynovial and extrasynovial flexor tendon autografts.

Authors:  M Noguchi; J G Seiler; N D Boardman; D M Tramaglini; R H Gelberman; S L Woo
Journal:  J Hand Surg Am       Date:  1997-05       Impact factor: 2.230

7.  Surface modification of extrasynovial tendon by chemically modified hyaluronic acid coating.

Authors:  Toshimitsu Momose; Peter C Amadio; Yu-Long Sun; Chunfeng Zhao; Mark E Zobitz; Jeffrey R Harrington; Kai-Nan An
Journal:  J Biomed Mater Res       Date:  2002-02

8.  The effect of suture technique on adhesion formation after flexor tendon repair for partial lacerations in a canine model.

Authors:  C Zhao; P C Amadio; T Momose; P Couvreur; M E Zobitz; K N An
Journal:  J Trauma       Date:  2001-11

9.  Remodeling of the gliding surface after flexor tendon repair in a canine model in vivo.

Authors:  Chunfeng Zhao; Peter C Amadio; Toshimitsu Momose; Mark E Zobitz; Paulus Couvreur; Kai-Nan An
Journal:  J Orthop Res       Date:  2002-07       Impact factor: 3.494

10.  Reducing friction by chemically modifying the surface of extrasynovial tendon grafts.

Authors:  Yu-Long Sun; Chao Yang; Peter C Amadio; Chunfeng Zhao; Mark E Zobitz; Kai-Nan An
Journal:  J Orthop Res       Date:  2004-09       Impact factor: 3.494

View more
  4 in total

1.  Local delivery of rhVEGF165 through biocoated nHA/coral block grafts in critical-sized dog mandible defects: a histological study at the early stages of bone healing.

Authors:  Bing Du; Yao Gao; Yue Deng; Yadong Zhao; Chunhua Lai; Zehong Guo; Mingdeng Rong; Lei Zhou
Journal:  Int J Clin Exp Med       Date:  2015-04-15

2.  Surface Modification with Chemically Modified Synovial Fluid for Flexor Tendon Reconstruction in a Canine Model in Vivo.

Authors:  Xiaoxi Ji; Ramona L Reisdorf; Andrew R Thoreson; Lawrence R Berglund; Steven L Moran; Gregory D Jay; Kai-Nan An; Peter C Amadio; Chunfeng Zhao
Journal:  J Bone Joint Surg Am       Date:  2015-06-17       Impact factor: 5.284

3.  Tendon gradient mineralization for tendon to bone interface integration.

Authors:  Jin Qu; Andrew R Thoreson; Qingshan Chen; Kai-Nan An; Peter C Amadio; Chunfeng Zhao
Journal:  J Orthop Res       Date:  2013-08-12       Impact factor: 3.494

4.  Angiogenesis and bone regeneration of porous nano-hydroxyapatite/coralline blocks coated with rhVEGF165 in critical-size alveolar bone defects in vivo.

Authors:  Bing Du; Weizhen Liu; Yue Deng; Shaobing Li; Xiangning Liu; Yan Gao; Lei Zhou
Journal:  Int J Nanomedicine       Date:  2015-03-31
  4 in total