Literature DB >> 8512409

Heparin coating reduces blood cell adhesion to arterial filters during coronary bypass: a clinical study.

J W Borowiec1, A Bylock, J van der Linden, S Thelin.   

Abstract

Deleterious effects of cardiopulmonary bypass (CPB) are partly sequelae of blood-foreign surface reactions. Coating the inner surfaces of CPB sets with heparin has been shown to decrease activation of humoral cascade systems. The aim of this study was to investigate whether the heparin-coated CPB sets influence adhesion of blood cells to surfaces of arterial filters during CPB. Thirty-one patients undergoing coronary artery bypass grafting were studied. In the control group (C) standard CPB sets and standard doses of heparin (300 IU/kg) were employed; in the HC (heparin-coated) group, heparin-coated CPB sets and reduced heparin doses (range, 150 to 225 IU/kg) were used. Two additional groups were also studied; group FC (coated filter), with standard CPB sets and heparin-coated arterial filters (heparin dose, 300 IU/kg), and group OC (uncoated filter), with heparin-coated CPB sets and standard arterial filters (heparin dose, 300 IU/kg). The inner surfaces of the arterial filters were examined after CPB with scanning electron microscopy. Scanning electron microscopy demonstrated almost clean surfaces in heparin-coated filters even when other parts of the circuit were uncoated. Using an arbitrary adhesion score, significant differences between the groups were noted in the adhesion grade; it was lowest in group HC (2.2 +/- 0.27 [mean +/- standard error of the mean]) versus group C (5.4 +/- 0.53; p < 0.001). In group FC it was marginally higher than in group HC but almost significantly lower than in group OC (2.6 +/- 0.68 versus 5.4 +/- 0.81; p = 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8512409     DOI: 10.1016/0003-4975(93)91106-w

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Cardiac surgical patients exposed to heparin-bonded circuits develop less postoperative cerebral dysfunction than patients exposed to non-heparin-bonded circuits.

Authors:  L B Mongero; J R Beck; H E Manspeizer; E J Heyer; K Lee; T A Spanier; C R Smith
Journal:  Perfusion       Date:  2001-03       Impact factor: 1.972

2.  A randomized study of coronary artery bypass surgery performed with the Resting Heart™ System utilizing a low vs a standard dosage of heparin.

Authors:  Johan Nilsson; Sara Scicluna; Gunnar Malmkvist; Leif Pierre; Lars Algotsson; Per Paulsson; Henrik Bjursten; Per Johnsson
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-08-21

3.  Protective effect of heparin-coated circuits on the platelets during cardiopulmonary bypass.

Authors:  Kailun Zhang; Zhiwei Hu; Yunhai Yang; Ruqing Huang; Huiming Fan; Zongquan Sun
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2003
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.