Protective effect of heparin-coated circuits on the platelets during cardiopulmonary bypass.

Kailun Zhang1, Zhiwei Hu, Yunhai Yang, Ruqing Huang, Huiming Fan, Zongquan Sun.   

Abstract

To observe the protective effect of heparin-coated circuits (HCC) on the platelet function during cardiopulmonary bypass (CPB), 23 patients with heart valve replacement were studied. The system heparin dose was 3 mg/kg in the control group (n = 15) and heparin-coated circuits in the HCC group (n = 8). Platelet count, alpha-granule membrane protein-140 (GMP-140) concentrations were determined before CPB, at 60 min of CPB, 30 and 60 min after protamine administration, first 12 h after CPB, respectively. At end of CPB the arterial filters in the circuits were observed by electron microscopy. The amount of first 12-h postoperative blood loss was measured. There was significant reduction in platelet loss during and after CPB in the HCC group in contrast to the control group during CPB (P<0.05). During the first 12 h, postoperative blood loss was reduced in the HCC group as compared with that in the control group (218+/-61 ml, vs. 332+/-118 ml, P<0.05). Electron microscopy showed that in the HCC group the filter meshes and their fringes were clear and fragments of floccules were occasionally seen, without adherent cells or only few adherent cells on their surfaces, whereas several cellular and fibrous components were found to adhere to the surfaces of the filter meshes in the control group. This study indicates that heparin-coated circuits might reduce the platelet loss and activation during CPB and improve hemocompatibility of cardiopulmonary bypass equipment.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 15015647     DOI: 10.1007/BF02829429

Source DB:  PubMed          Journal:  J Huazhong Univ Sci Technolog Med Sci        ISSN: 1672-0733


  9 in total

1.  Cardiopulmonary bypass leads to a preferential loss of activated platelets. A flow cytometric assay of platelet surface antigens.

Authors:  A Wahba; G Black; M Koksch; G Rothe; J Preuner; G Schmitz; D E Birnbaum
Journal:  Eur J Cardiothorac Surg       Date:  1996       Impact factor: 4.191

2.  The effects of Carmeda Bioactive Surface on human blood components during simulated extracorporeal circulation.

Authors:  R L Korn; C A Fisher; E R Livingston; N Stenach; S J Fishman; V Jeevanadam; V P Addonizio
Journal:  J Thorac Cardiovasc Surg       Date:  1996-05       Impact factor: 5.209

3.  GMP-140 mediates adhesion of stimulated platelets to neutrophils.

Authors:  S A Hamburger; R P McEver
Journal:  Blood       Date:  1990-02-01       Impact factor: 22.113

4.  High and low heparin dose with heparin-coated cardiopulmonary bypass: activation of complement and granulocytes.

Authors:  E Ovrum; T E Mollnes; E Fosse; E A Holen; G Tangen; M A Ringdal; V Videm
Journal:  Ann Thorac Surg       Date:  1995-12       Impact factor: 4.330

Review 5.  Coating-techniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation.

Authors:  H P Wendel; G Ziemer
Journal:  Eur J Cardiothorac Surg       Date:  1999-09       Impact factor: 4.191

6.  Evaluation of heparin-coated circuits with full heparin dose strategy.

Authors:  V Sinci; S Kalaycioglu; S Gunaydin; Y Imren; L Gokgoz; H Soncul; A Ersoz
Journal:  Ann Thorac Cardiovasc Surg       Date:  1999-06       Impact factor: 1.520

7.  Comparison of platelet membrane markers for the detection of platelet activation in vitro and during platelet storage and cardiopulmonary bypass surgery.

Authors:  M J Metzelaar; J Korteweg; J J Sixma; H K Nieuwenhuis
Journal:  J Lab Clin Med       Date:  1993-04

8.  A heparin-coated circuit maintains platelet aggregability in response to shear stress in an in vitro model of cardiopulmonary bypass.

Authors:  I Hioki; M Nishikawa; K Onoda; T Shimono; H Shimpo; K Tanaka; Y Suzuki; H Shiku; Y Ikeda; I Yada
Journal:  Thromb Haemost       Date:  1998-09       Impact factor: 5.249

9.  Heparin coating reduces blood cell adhesion to arterial filters during coronary bypass: a clinical study.

Authors:  J W Borowiec; A Bylock; J van der Linden; S Thelin
Journal:  Ann Thorac Surg       Date:  1993-06       Impact factor: 4.330

  9 in total
  1 in total

1.  Evaluation of biocompatible cardiopulmonary bypass circuit use during pediatric open heart surgery.

Authors:  Joseph Deptula; Kimberly Glogowski; Kellie Merrigan; Kim Hanson; Donald Felix; James Hammel; Kim Duncan
Journal:  J Extra Corpor Technol       Date:  2006-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.