Transstenotic coronary pressure gradient measurement in humans: in vitro and in vivo evaluation of a new pressure monitoring angioplasty guide wire.

B De Bruyne1, N H Pijls, W J Paulus, P J Vantrimpont, S U Sys, G R Heyndrickx.   

Abstract

OBJECTIVES: The present study was designed to investigate 1) the feasibility and accuracy of coronary pressure measurements with a novel 0.015-in. (0.038 cm) fluid-filled guide wire, and 2) the effect of the guide wire itself on stenosis hemodynamics.
BACKGROUND: To assess the functional results of coronary angioplasty, measurements of the transstenotic pressure gradient have been advocated. However, this gradient is no longer routinely measured because it is not reliable when determined with the angioplasty catheter.
METHODS: A fluid-filled 0.015-in. guide wire to be connected to a conventional pressure transducer was developed. Five wires were tested for their frequency response characteristics and for their accuracy in measuring hydrostatic pressure. In an in vitro model of stenosis (reference diameter 4 mm), the pressure gradient was determined at incremental flow levels for varying stenosis severity with and without a 0.015-in. guide wire through the narrowing. In 37 patients, the transstenotic pressure gradient was measured before and after angioplasty and compared with obstruction area and percent area stenosis as determined by quantitative coronary angiography.
RESULTS: The correlation between the actual pressure and the pressure recorded by the guide wire was excellent (r = 0.98) despite a slight underestimation (-3 +/- 5%). Phasic pressure recordings were precluded by a long time constant of 16 +/- 4 s. The presence of the guide wire produced a significant overestimation (> 20%) of the pressure decrease only in cases of tight stenosis (> 90% area reduction). Furthermore, a theoretic model based on the fluid dynamic equation predicted that this overestimation was inversely proportional to the reference diameter of the vessel, yet was only slightly influenced by the flow. The lesion was crossed in all but one patient (97%) and pressure gradient was recorded throughout the study in 34 (94%) of 36 patients. The mean pressure gradient decreased from 30 +/- 19 before to 3 +/- 5 mm Hg after angioplasty (p < 0.01). A curvilinear relation was found between the pressure gradient and both percent area stenosis (r2 = 0.67) and obstruction area (r2 = 0.72). A sharp increase in pressure gradient was noted once the stenosis exceeded 75% area reduction.
CONCLUSIONS: Mean transstenotic pressure gradients can be easily and reliably recorded with a 0.015-in. fluid-filled guide wire. This ability should facilitate the functional assessment of coronary stenoses of intermediate severity and of immediate postangioplasty results.

Entities:  

Mesh:

Year:  1993        PMID: 8509531     DOI: 10.1016/0735-1097(93)90825-l

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  29 in total

Review 1.  Reasons and implications of agreements and disagreements between coronary flow reserve, fractional flow reserve, and myocardial perfusion imaging.

Authors:  Manish Motwani; Mahsaw Motlagh; Anuj Gupta; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2015-12-29       Impact factor: 5.952

2.  Postprocedural resistance of the target lesion is a strong predictor of subsequent revascularization: assessment by a novel lesion-specific physiological parameter, the epicardial resistance index.

Authors:  Kazuhito Suzuki; Yukio Tsurumi; Yuji Fuda; Yasuhiro Ishii; Atsushi Takagi; Nobuhisa Hagiwara; Hiroshi Kasanuki
Journal:  Heart Vessels       Date:  2007-05-21       Impact factor: 2.037

3.  Treating stable ischemic heart disease with percutaneous coronary intervention - The debate continues.

Authors:  Rishi Puri; Stephen J Nicholls
Journal:  Cardiovasc Diagn Ther       Date:  2012-12

4.  Efficiencies of intracoronary sodium nitroprusside on fractional flow reserve measurement.

Authors:  Shaosheng Li; Jie Deng; Xiaozeng Wang; Xin Zhao; Yaling Han
Journal:  Int J Clin Exp Med       Date:  2015-02-15

5.  Characteristics of the flow velocity-pressure gradient relation in the assessment of stenoses: an in vitro study.

Authors:  K M J Marques; N Westerhof
Journal:  Neth Heart J       Date:  2008-05       Impact factor: 2.380

Review 6.  Coronary artery disease, valvular heart disease, bradycardia, and heart failure.

Authors:  E Smith; H Powell; I R Hastie
Journal:  Postgrad Med J       Date:  1995-06       Impact factor: 2.401

7.  Measurement of coronary flow reserve by noninvasive cardiac imaging.

Authors:  Alberto Cuocolo; Mario Petretta; Andrea Soricelli
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06       Impact factor: 9.236

Review 8.  Coronary Angiography With Pressure Wire and Fractional Flow Reserve.

Authors:  Luise Gaede; Helge Möllmann; Tanja Rudolph; Johannes Rieber; Florian Boenner; Monique Tröbs
Journal:  Dtsch Arztebl Int       Date:  2019-03-22       Impact factor: 5.594

Review 9.  Recent insights into the treatment of stable CAD : FFR-guided PCI vs. medical therapy.

Authors:  L X van Nunen; P A L Tonino
Journal:  Herz       Date:  2013-06       Impact factor: 1.443

10.  Coronary pressure measurement based decision making for percutaneous coronary intervention.

Authors:  Kohichiro Iwasaki; Shozo Kusachi
Journal:  Curr Cardiol Rev       Date:  2009-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.