Literature DB >> 8508935

Absorbed doses from computed tomography for dental implant surgery: comparison with conventional tomography.

A Ekestubbe1, A Thilander, K Gröndahl, H G Gröndahl.   

Abstract

Tomography is often needed prior to implant surgery to evaluate jaw bone dimensions. Computed tomography (CT) is advocated as an alternative. The purpose of this study was to measure the absorbed doses to radiosensitive organ in the head and neck region when CT is used. Measurements were made with extruded LiF thermoluminescent dosemeters within and on an anthropomorphic phantom examined with a Philips Tomoscan LX CT scanner. Axial scanning was performed for the maxilla and both frontal, perpendicular to the alveolus, and axial for the mandible. The highest absorbed doses were at the skin surface, 38 mGy with maxillary scans, and from axial and frontal scans of the mandible 35 mGy and 37 Gy, respectively. The parotid dose was 31 mGy from maxillary scans and in the mandible the submandibular gland dose was 27 mGy with axial scanning and 16 mGy with frontal. The eye lens received its highest dose (5.5 mGy) from frontal scans of the mandible. Although outside the scanning plane the pituitary and the thyroid glands received comparatively high absorbed doses of 0.6-4.0 mGy. All organ doses measured were considerably higher than those reported for conventional tomography.

Entities:  

Mesh:

Year:  1993        PMID: 8508935     DOI: 10.1259/dmfr.22.1.8508935

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  6 in total

1.  Digital tomosynthesis-experiences with a new imaging device for the dental field.

Authors:  Christoph M Ziegler; Manfred Franetzki; Tina Denig; Joachim Mühling; Stefan Hassfeld
Journal:  Clin Oral Investig       Date:  2003-02-18       Impact factor: 3.573

2.  In vivo comparison of conventional and cone beam CT synthesized cephalograms.

Authors:  Vandana Kumar; John Ludlow; Lucia Helena Soares Cevidanes; André Mol
Journal:  Angle Orthod       Date:  2008-09       Impact factor: 2.079

3.  [Radiation exposure and 3 dimensional imaging options of SIREMOBIL Iso-C(3D) for planning surgical dental interventions].

Authors:  M Heiland; D Schulze; S Flinzberg; H Thurmann; U Rother; R Schmelzle
Journal:  Mund Kiefer Gesichtschir       Date:  2004-01-22

4.  Assessing the amount of interdental bone in posterior areas of the mandible for placing orthodontic mini-implants.

Authors:  Nasrin Esfahanizadeh; Damoun Shahraki; Hamidreza Daneshparvar; Ahmad Reza Talaei Pour; Mohammad Ali Saghiri; Ahmad Sheibaninia; Shadab Rashtak
Journal:  J Dent (Tehran)       Date:  2013-05

5.  Association between Marginal Bone Loss and Bone Quality at Dental Implant Sites Based on Evidence from Cone Beam Computed Tomography and Periapical Radiographs.

Authors:  Amir Eskandarloo; Reza Arabi; Mohsen Bidgoli; Faezeh Yousefi; Jalal Poorolajal
Journal:  Contemp Clin Dent       Date:  2019 Jan-Mar

6.  The accuracy of single emulsion radiographic film in linear measurement of spiral tomography.

Authors:  Arash Dabbaghi; Ali Shokraneh; Nastaran Farhadi
Journal:  Dent Res J (Isfahan)       Date:  2013-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.