Literature DB >> 8505901

Nontriggered magnetic resonance velocity measurement of the time-average of pulsatile velocity.

M B Hofman1, M Kouwenhoven, M Sprenger, A C van Rossum, J Valk, N Westerhof.   

Abstract

The feasibility of the determination of the time-average of pulsatile velocity obtained via a nontriggered magnetic resonance (MR) acquisition is studied. The advantage of this method, in comparison with a triggered acquisition, is a considerable reduction (approximately 15x) in acquisition time. However, pulsatility causes image artifacts, known as ghosts, and the Fourier transform technique required for the imaging procedure accomplishes time-averaging of the complex MR signal. Both effects can result in errors in the velocity determined. Calculations show that these errors depend on the velocity time function and the acquisition parameters. In vivo comparison of triggered and nontriggered MR velocity measurements in the femoral artery of volunteers (n = 7) shows larger statistical and systematic errors in the latter, which depend on the excitation angle. Therefore, this nontriggered average velocity measurement is only useful as a fast and rough estimation of the time-averaged velocity.

Mesh:

Year:  1993        PMID: 8505901     DOI: 10.1002/mrm.1910290511

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Variation in supratentorial cerebrospinal fluid production rate in one day: measurement by nontriggered phase-contrast magnetic resonance imaging.

Authors:  Hiroto Takahashi; Hisashi Tanaka; Norihiko Fujita; Kenya Murase; Noriyuki Tomiyama
Journal:  Jpn J Radiol       Date:  2011-02-27       Impact factor: 2.374

2.  Measurement of flow in small vessels by magnetic resonance phase mapping techniques: an in vitro and in vivo study.

Authors:  P E Summers; S R Parsons; M G Taylor; P B Deverall; T S Padayachee
Journal:  MAGMA       Date:  1997-06       Impact factor: 2.310

3.  Optimized analysis of blood flow and wall shear stress in the common carotid artery of rat model by phase-contrast MRI.

Authors:  Shin-Lei Peng; Cheng-Ting Shih; Chiun-Wei Huang; Shao-Chieh Chiu; Wu-Chung Shen
Journal:  Sci Rep       Date:  2017-07-12       Impact factor: 4.379

Review 4.  Non-Invasive Evaluation of Cerebral Microvasculature Using Pre-Clinical MRI: Principles, Advantages and Limitations.

Authors:  Bram Callewaert; Elizabeth A V Jones; Uwe Himmelreich; Willy Gsell
Journal:  Diagnostics (Basel)       Date:  2021-05-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.