Literature DB >> 8500866

Accuracy of a continuous blood pressure monitor based on arterial tonometry.

T Sato1, M Nishinaga, A Kawamoto, T Ozawa, H Takatsuji.   

Abstract

A validation study of the continuous noninvasive tonometric blood pressure monitor called JENTOW was performed in 20 normotensive subjects and 10 hypertensive patients. Tonometric and intra-arterial blood pressures were simultaneously recorded at supine rest and during a Valsalva maneuver and tilting test. The results of the strict evaluation of the instrument's capacity for reproducing intra-arterial blood pressure were as follows: 1) The overall frequency response of the transcutaneous blood pressure-monitoring system based on arterial tonometry was flat, with negligible delay to intra-arterial blood pressure in the range of 0-5 Hz. 2) The largest discrepancy between intra-arterial and tonometric pressure waveforms was found at the early systolic phase; except for this phase, the tonometric waveform was almost equal to the intra-arterial waveform. 3) The beat-to-beat variability of tonometric pressure corresponded to that of intra-arterial pressure almost perfectly in the physiologically significant frequency range of 0-0.5 Hz. 4) During resting conditions, the averages of the systolic and diastolic values measured tonometrically corresponded well to those measured intra-arterially. 5) The changes in the between-method discrepancy of blood pressure values during the Valsalva maneuver were statistically significant but small (< 5 mm Hg). 6) No significant effect of postural tilting was found on the between-method discrepancy. We conclude that this method is clinically acceptable and reliable except for its limited capacity for recording the higher frequency intra-arterial waveform and for responding to the relatively rapid and large transient changes in blood pressure.

Entities:  

Mesh:

Year:  1993        PMID: 8500866     DOI: 10.1161/01.hyp.21.6.866

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  27 in total

1.  Blood pressure response to force-velocity properties of the knee-hip extension movement.

Authors:  Junichiro Yamauchi; Satoshi Nakayama; Naokata Ishii
Journal:  Eur J Appl Physiol       Date:  2007-12-04       Impact factor: 3.078

Review 2.  Heart rate variability in athletes.

Authors:  André E Aubert; Bert Seps; Frank Beckers
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

3.  Chronic physical activity mitigates cerebral hypoperfusion during central hypovolemia in elderly humans.

Authors:  Kevin Formes; Peizhen Zhang; Nancy Tierney; Frederick Schaller; Xiangrong Shi
Journal:  Am J Physiol Heart Circ Physiol       Date:  2009-12-31       Impact factor: 4.733

4.  Effect of combined resistance and aerobic training on reactive hyperemia in men.

Authors:  Hiroshi Kawano; Kouhei Fujimoto; Mitsuru Higuchi; Motohiko Miyachi
Journal:  J Physiol Sci       Date:  2009-08-18       Impact factor: 2.781

5.  Considerations for SphygmoCor radial artery pulse wave analysis: side selection and peripheral arterial blood pressure calibration.

Authors:  Jeffrey S Martin; Alexandra R Borges; John B Christy; Darren T Beck
Journal:  Hypertens Res       Date:  2015-03-19       Impact factor: 3.872

Review 6.  Non-invasive continuous blood pressure monitoring: a review of current applications.

Authors:  Elena Chung; Guo Chen; Brenton Alexander; Maxime Cannesson
Journal:  Front Med       Date:  2013-01-23       Impact factor: 4.592

7.  Homocysteine levels are associated with the results of 123I-metaiodobenzylguanidine myocardial scintigraphy in type 2 diabetic patients.

Authors:  Futoshi Anan; Hidetoshi Yonemochi; Takayuki Masaki; Naohiko Takahashi; Mikiko Nakagawa; Nobuoki Eshima; Tetsunori Saikawa; Hironobu Yoshimatsu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-08-04       Impact factor: 9.236

8.  Development of a new method for assessing the cardiac baroreflex: response to downward tilting in patients with diabetes mellitus.

Authors:  M Nakagawa; N Takahashi; T Ooie; K Yufu; M Hara; M Watanabe; S Nobe; H Yonemochi; I Katsuragi; T Okeda; T Sakata; T Saikawa
Journal:  Heart       Date:  2001-12       Impact factor: 5.994

9.  Cerebral blood flow and autoregulation: current measurement techniques and prospects for noninvasive optical methods.

Authors:  Sergio Fantini; Angelo Sassaroli; Kristen T Tgavalekos; Joshua Kornbluth
Journal:  Neurophotonics       Date:  2016-06-21       Impact factor: 3.593

10.  A somatostatin analog improves tilt table tolerance by decreasing splanchnic vascular conductance.

Authors:  S S Jarvis; J P Florian; M J Curren; J A Pawelczyk
Journal:  J Appl Physiol (1985)       Date:  2012-02-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.