Porosity of bone cement reduced by mixing and collecting under vacuum.

J S Wang1, H Franzén, E Jonsson, L Lidgren.   

Abstract

Palacos R bone cement was mixed in a commercial vacuum mixing system (MITAB), and in an experimental system allowing evacuating air from the powder before mixing and collecting the cement under partial vacuum. The effect on the porosity of mixing at different pressure levels was tested. The effect of evacuating air from the powder before mixing was also analyzed. The numbers and sizes of the voids in the cement samples were measured in radiographs and under the microscope. Also, the density of the cement was measured. Vacuum mixed samples had a substantial reduction of voids, as well as an increase in density compared to mixing at atmospheric pressure. After vacuum mixing and collection, a further reduction of the porosity and increased density were seen; all the large voids within the cement were eliminated at 0.05 bar absolute pressure.

Mesh:

Substances:

Year:  1993        PMID: 8498171     DOI: 10.3109/17453679308994555

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  6 in total

1.  Fatigue of bone cement with simulated stem interface porosity.

Authors:  S Tepic; U Soltész
Journal:  J Mater Sci Mater Med       Date:  1998-12       Impact factor: 3.896

2.  Multi-technique characterization of retrieved bone cement from revised total hip arthroplasties.

Authors:  T Eliades; J S Papadopulos; G Eliades; N Silikas; D C Watts
Journal:  J Mater Sci Mater Med       Date:  2003-11       Impact factor: 3.896

3.  Masquelet technique: The effect of altering implant material and topography on membrane matrix composition, mechanical and barrier properties in a rat defect model.

Authors:  Natalie Gaio; Alice Martino; Zacharie Toth; J Tracy Watson; Daemeon Nicolaou; Sarah McBride-Gagyi
Journal:  J Biomech       Date:  2018-02-27       Impact factor: 2.712

4.  The effect of varying percentage hydroxyapatite in poly(ethylmethacrylate) bone cement on human osteoblast-like cells.

Authors:  T N Opara; M J Dalby; E J Harper; L Di Silvio; W Bonfield
Journal:  J Mater Sci Mater Med       Date:  2003-03       Impact factor: 3.896

5.  Enhanced HAPEX topography: comparison of osteoblast response to established cement.

Authors:  M J Dalby; W Bonfield; L Di Silvio
Journal:  J Mater Sci Mater Med       Date:  2003-08       Impact factor: 3.896

6.  The long-term in vivo behavior of polymethyl methacrylate bone cement in total hip arthroplasty.

Authors:  Hiroyuki Oonishi; Haruhiko Akiyama; Mitsuru Takemoto; Toshiyuki Kawai; Koji Yamamoto; Takao Yamamuro; Hironobu Oonishi; Takashi Nakamura
Journal:  Acta Orthop       Date:  2011-10       Impact factor: 3.717

  6 in total