Measuring lung volumes in advanced asbestosis: comparability of plethysmographic and radiographic versus helium rebreathing and single breath methods.

K H Kilburn1, A Miller, R H Warshaw.   

Abstract

Total lung capacity was measured in 16 workers with pulmonary asbestosis using four standard methods: body plethysmography, radiographic lung area, helium dilution by multiple breath and by single breath (alveolar volume). All men had irregular opacities of ILO profusion category 2/1 or greater and four had pleural plaques in addition. The radiographic and plethysmographic methods produced virtually identical mean values for TLC of 7.52 l and 7.64 l and for RV of 4.06 l and 4.32 l and all values were larger than those by helium dilution. The closed circuit helium dilution method systematically underestimated TLC with a mean of 5.89 l as did single breath helium dilution with a mean of 6.39 l. These men had a larger mean RV/TLC, measuring 56.9% by body plethysmography and 54.6% by X-ray area than by the rebreathing dilutional method which was 43.8%. Air trapping within a normal TLC which characterizes asbestosis is revealed by radiographic and plethysmographic methods but concealed by gas dilution methods. Use of the latter is at least partly responsible for the impression that asbestosis is a 'restrictive disease'.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8497680     DOI: 10.1016/0954-6111(93)90138-p

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  4 in total

1.  Validation of a Novel Compact System for the Measurement of Lung Volumes.

Authors:  Kenneth I Berger; Ori Adam; Roberto Walter Dal Negro; David A Kaminsky; Robert J Shiner; Felip Burgos; Frans H C de Jongh; Inon Cohen; Jeffrey J Fredberg
Journal:  Chest       Date:  2021-02-02       Impact factor: 10.262

2.  Spirometry values for detecting a restrictive pattern in occupational health settings.

Authors:  Amir Houshang Mehrparvar; Mohammad Javad Zare Sakhvidi; Mehrdad Mostaghaci; Mohmmad Hossein Davari; Seyed Hesam Hashemi; Zohreh Zare
Journal:  Tanaffos       Date:  2014

3.  Clinical Roles of Lung Volumes Detected by Body Plethysmography and Helium Dilution in Asthmatic Patients: A Correlation and Diagnosis Analysis.

Authors:  Jian Luo; Dan Liu; Guo Chen; Binmiao Liang; Chuntao Liu
Journal:  Sci Rep       Date:  2017-01-18       Impact factor: 4.379

4.  Can the single-breath helium dilution method predict lung volumes as measured by whole-body plethysmography?

Authors:  Patrícia Chaves Coertjens; Marli Maria Knorst; Anelise Dumke; Adriane Schmidt Pasqualoto; João Riboldi; Sérgio Saldanha Menna Barreto
Journal:  J Bras Pneumol       Date:  2013 Nov-Dec       Impact factor: 2.624

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.