Ultrasound-assisted cannulation of the internal jugular vein. A prospective comparison to the external landmark-guided technique.

B G Denys1, B F Uretsky, P S Reddy.   

Abstract

BACKGROUND: Central venous access is an essential part of patient management in many clinical settings and is usually achieved with a blinded, external landmark-guided technique. The purpose of this study is to evaluate whether an ultrasound technique can improve on the traditional method. METHODS AND
RESULTS: We prospectively evaluated an ultrasound-guided method in 302 patients undergoing internal jugular venous cannulation and compared the results with 302 patients in whom an external landmark-guided technique was used. Ultrasound was used exclusively in an additional 626 patients. Cannulation of the internal jugular vein was achieved in all patients (100%) using ultrasound and in 266 patients (88.1%) using the landmark-guided technique (p < 0.001). The vein was entered on the first attempt in 78% of patients using ultrasound and in 38% using the landmark technique (p < 0.001). Average access time (skin to vein) was 9.8 seconds (2-68 seconds) by the ultrasound approach and 44.5 seconds (2-1,000 seconds) by the landmark approach (p < 0.001). Using ultrasound, puncture of the carotid artery occurred in 1.7% of patients, brachial plexus irritation in 0.4%, and hematoma in 0.2%. In the external landmark group, puncture of the carotid artery occurred in 8.3% of patients (p < 0.001), brachial plexus irritation in 1.7% (p < 0.001), and hematoma in 3.3% (p < 0.001).
CONCLUSIONS: Ultrasound-guided cannulation of the internal jugular vein significantly improves success rate, decreases access time, and reduces complication rate. These results suggest that this technique may be preferred in complicated cases or when access problems are anticipated.

Entities:  

Mesh:

Year:  1993        PMID: 8491011     DOI: 10.1161/01.cir.87.5.1557

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  79 in total

1.  Ultrasound guided central venous access.

Authors:  Manfred Muhm
Journal:  BMJ       Date:  2002-12-14

2.  Simulation-based training improves applied clinical placement of ultrasound-guided PICCs.

Authors:  Pamela Andreatta; Yifang Chen; Michael Marsh; Kyung Cho
Journal:  Support Care Cancer       Date:  2010-03-20       Impact factor: 3.603

3.  Ultrasound-guided central venous cannulation is superior to quick-look ultrasound and landmark methods among inexperienced operators: a prospective randomized study.

Authors:  Norair Airapetian; Julien Maizel; François Langelle; Santhi Samy Modeliar; Dimitrios Karakitsos; Herve Dupont; Michel Slama
Journal:  Intensive Care Med       Date:  2013-09-12       Impact factor: 17.440

Review 4.  Should ultrasound guidance be used for central venous catheterisation in the emergency department?

Authors:  P Atkinson; A Boyle; S Robinson; G Campbell-Hewson
Journal:  Emerg Med J       Date:  2005-03       Impact factor: 2.740

Review 5.  Venous access: a practical review for 2009.

Authors:  Edward Cheung; Mark O Baerlocher; Murray Asch; Andrew Myers
Journal:  Can Fam Physician       Date:  2009-05       Impact factor: 3.275

Review 6.  International evidence-based recommendations on ultrasound-guided vascular access.

Authors:  Massimo Lamperti; Andrew R Bodenham; Mauro Pittiruti; Michael Blaivas; John G Augoustides; Mahmoud Elbarbary; Thierry Pirotte; Dimitrios Karakitsos; Jack Ledonne; Stephanie Doniger; Giancarlo Scoppettuolo; David Feller-Kopman; Wolfram Schummer; Roberto Biffi; Eric Desruennes; Lawrence A Melniker; Susan T Verghese
Journal:  Intensive Care Med       Date:  2012-05-22       Impact factor: 17.440

Review 7.  Ultrasonography as a guide during vascular access procedures and in the diagnosis of complications.

Authors:  A Vezzani; T Manca; A Vercelli; A Braghieri; A Magnacavallo
Journal:  J Ultrasound       Date:  2013-10-29

Review 8.  Central venous access: techniques and indications in oncology.

Authors:  Pierre-Yves Marcy
Journal:  Eur Radiol       Date:  2008-05-06       Impact factor: 5.315

9.  Ultrasound-guided femoral dialysis access placement: a single-center randomized trial.

Authors:  Mayoor V Prabhu; Deven Juneja; Palepu B Gopal; Mohan Sathyanarayanan; Sreepada Subhramanyam; Sridhar Gandhe; K Shivanand Nayak
Journal:  Clin J Am Soc Nephrol       Date:  2009-12-03       Impact factor: 8.237

10.  Radiological placement of chest ports in pediatric oncology patients.

Authors:  Barbaros E Cil
Journal:  Eur Radiol       Date:  2004-07-13       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.