Literature DB >> 8487170

Contrast sensitivity and glare in patients with a diffractive multifocal intraocular lens.

A Winther-Nielsen1, L Corydon, T Olsen.   

Abstract

Contrast sensitivity was measured in 25 patients who had a multifocal diffractive intraocular lens and in 23 control patients with a monofocal lens in four simulated light conditions: (1) daylight, (2) daylight with peripheral glare, (3) twilight, (4) twilight with central glare. In normal daylight and twilight, contrast sensitivity of the multifocal group was significantly lower than the control group's (P < .05). The difference was 0.13 log units for the multifocal group and 0.17 log units for the control group (mean value across the tested frequency from 1.5 to 18 cycles/deg). Peripheral glare reduced contrast sensitivity under daylight conditions in both groups (P < .05), but the loss did not differ significantly between the two (P > .05). Central glare reduced contrast sensitivity under twilight conditions in both groups (P < .05), with the greatest loss in the multifocal patients (P < .001). We conclude that the most significant loss of contrast sensitivity in patients with the diffractive multifocal intraocular lens is found with central glare under twilight conditions.

Entities:  

Mesh:

Year:  1993        PMID: 8487170     DOI: 10.1016/s0886-3350(13)80952-2

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  All-distance visual acuity in eyes with a nontinted or a yellow-tinted diffractive multifocal intraocular lens.

Authors:  Ken Hayashi; Miki Masumoto; Hideyuki Hayashi
Journal:  Jpn J Ophthalmol       Date:  2009-03-31       Impact factor: 2.447

2.  Development of a Headlight Glare Simulator for a Driving Simulator.

Authors:  Alex D Hwang; Eli Peli
Journal:  Transp Res Part C Emerg Technol       Date:  2013-07-01       Impact factor: 8.089

3.  Halo size under distance and near conditions in refractive multifocal intraocular lenses.

Authors:  S Pieh; B Lackner; G Hanselmayer; R Zöhrer; M Sticker; H Weghaupt; A Fercher; C Skorpik
Journal:  Br J Ophthalmol       Date:  2001-07       Impact factor: 4.638

4.  Comparison of higher-order aberration and contrast sensitivity in monofocal and multifocal intraocular lenses.

Authors:  Chang Yeom Kim; So-Hyang Chung; Tae-Im Kim; Young Jae Cho; Geunyoung Yoon; Kyoung Yul Seo
Journal:  Yonsei Med J       Date:  2007-08-31       Impact factor: 2.759

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.