Literature DB >> 8482623

A CT-based evaluation method for permanent implants: application to prostate.

J N Roy1, K E Wallner, P J Harrington, C C Ling, L L Anderson.   

Abstract

A computerized tomography-based 3-dimensional evaluation scheme, using semi-automatic seed localization from transverse computerized tomography-images, has been developed for permanent implants. The treatment isodose contour is generated at each scan plane and overlaid on the corresponding target contour for coverage visualization. Volume and surface dose histograms are generated for the target and neighboring normal structures. Dose inhomogeneity within the target is also estimated from the full-width at half maximum of the differential volume dose histogram. The matched peripheral dose is calculated from the ellipsoidal volume approximation for the target. The present evaluation method has been applied here to 10 actual permanent I-125 prostatic implantations. Coverages by 150 Gy and 100 Gy levels are found to range from 78-96% and 91-99% of the target volume, respectively. The average matched peripheral dose is found to be about two times the average peripheral dose (the dose encompassing 99% target) and about three times the average minimum peripheral dose (the dose encompassing 100% target). The dose inhomogeneities within the target volume, in these 10 cases, range from 220-420 Gy.

Mesh:

Year:  1993        PMID: 8482623     DOI: 10.1016/0360-3016(93)90188-2

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

1.  Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

2.  Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

Review 3.  Permanent interstitial brachytherapy for prostate cancer: a current review.

Authors:  Jeffrey Woolsey; Nicole Miller; Dan Theodorescu
Journal:  World J Urol       Date:  2003-08-13       Impact factor: 4.226

Review 4.  Alternative therapies for localized prostate cancer.

Authors:  Harrie P Beerlage
Journal:  Curr Urol Rep       Date:  2003-06       Impact factor: 2.862

5.  A magnetic resonance-based seed localization method for I-125 prostate implants.

Authors:  Rena J Lee; Hyun Suk Suh; Kyung Ja Lee; Soome Lim; Yookyung Kim; Sungkyu Kim; Jinho Choi
Journal:  J Korean Med Sci       Date:  2007-09       Impact factor: 2.153

6.  Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department.

Authors:  Maree T Izatt; Deborah Lees; Susan Mills; Caroline A Grant; J Paige Little
Journal:  BMJ Open       Date:  2019-08-01       Impact factor: 2.692

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.