Literature DB >> 8475301

Improved parameters for unsharp mask filtering of digital chest radiographs.

M Prokop1, C M Schaefer, J W Oestmann, M Galanski.   

Abstract

Observer performance with four unsharp mask filtering algorithms for storage phosphor chest radiographs was compared with that with conventional screen-film radiographs in the detection of three types of simulated lung disease: nodules, fine lines, and micronodule clusters. Previously studied parameter sets (small [1.4-mm] and medium [5-mm] filter masks) and two new parameter sets (large [2.5-cm] and ultralarge [7-cm] masks) were compared by means of receiver operating characteristic analysis. With medium and small masks, nodule detection was inferior to that achieved with other modes. Use of ultralarge masks decreased the detection of lines compared with detection with conventional screen-film radiographs. Although detection of micronodule clusters was worse with digital images than with conventional screen-film radiographs, results with large and ultralarge masks were better than with small masks. Overall, filtering with large masks was best suited for simultaneously matching linear, nodular, and micronodular structures. These results suggest that lesion-specific processing of digital chest images is not necessary.

Entities:  

Mesh:

Year:  1993        PMID: 8475301     DOI: 10.1148/radiology.187.2.8475301

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Fast adaptive unsharp masking with programmable mediaprocessors.

Authors:  Unmin Bae; Vijay Shamdasani; Ravi Managuli; Yongmin Kim
Journal:  J Digit Imaging       Date:  2003-10-20       Impact factor: 4.056

2.  Interactive image enhancement of CR and DR images.

Authors:  Maikael A Thomas; Alan H Rowberg; Steve G Langer; Yongmin Kim
Journal:  J Digit Imaging       Date:  2004-06-04       Impact factor: 4.056

3.  Two K versus 4 K storage phosphor chest radiography: detection performance and image quality.

Authors:  Claus Koelblinger; Mathias Prokop; Michael Weber; Johannes Sailer; Fabiola Cartes-Zumelzu; Cornelia Schaefer-Prokop
Journal:  Eur Radiol       Date:  2007-05-10       Impact factor: 5.315

4.  Effect of multiscale processing in digital chest radiography on automated detection of lung nodule with a computer assistance system.

Authors:  Qian He; Wen He; Keyang Wang; Daqing Ma
Journal:  J Digit Imaging       Date:  2008-02-01       Impact factor: 4.056

5.  Quantitative measurement method for possible rib fractures in chest radiographs.

Authors:  Jaeil Kim; Sungjun Kim; Young Jae Kim; Kwang Gi Kim; Jinah Park
Journal:  Healthc Inform Res       Date:  2013-09-30

6.  Digital chest radiography: clinical aspects.

Authors:  U Tylén
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.