A preoperative reliable recording of the knee alignment is necessary to calculate the correct wedge at high tibial osteotomy for medial gonarthrosis. To determine the reproducibility of the hip-knee-ankle angle (HKA), a preoperative, whole lower limb roentgenogram was obtained twice in eight patients, and each roentgenogram was judged by two radiologists. Assessment of the HKA had a variability of at most 2 degrees, which is highly significant for a reliable calculation of the wedge at tibial osteotomy.

Entities:  

Mesh:

Year:  1993        PMID: 8472414

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  20 in total

1.  Length and angle measurements of the lower extremity in digital composite overview images.

Authors:  M Boewer; H Arndt; P A W Ostermann; J Petersein; S Mutze
Journal:  Eur Radiol       Date:  2004-05-26       Impact factor: 5.315

2.  [Possibilities of computer-assisted navitation in knee para-articular osteotomies].

Authors:  J Menetrey; M Paul
Journal:  Orthopade       Date:  2004-02       Impact factor: 1.087

3.  [Tibial realignment with external fixator].

Authors:  F Geiger; D Sabo
Journal:  Orthopade       Date:  2004-02       Impact factor: 1.087

4.  Predictive factors for the progression of spontaneous osteonecrosis of the knee.

Authors:  Y Akamatsu; H Kobayashi; Y Kusayama; M Aratake; K Kumagai; T Saito
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-14       Impact factor: 4.342

5.  Applicability of a modified angular correction measurement method for open-wedge high tibial osteotomy.

Authors:  James Moore; Lydia Mychaltchouk; Frédéric Lavoie
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-02       Impact factor: 4.342

6.  Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method.

Authors:  Y Akamatsu; N Mitsugi; Y Mochida; N Taki; H Kobayashi; R Takeuchi; T Saito
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-29       Impact factor: 4.342

7.  Radiation dose reduction in plain radiography of the full-length lower extremity and full spine.

Authors:  Mi Ran Jeon; Hee Jin Park; So Yeon Lee; Kyung A Kang; Eun Young Kim; Hyun Pyo Hong; Inyoung Youn
Journal:  Br J Radiol       Date:  2017-10-27       Impact factor: 3.039

8.  Minimally invasive opening wedge tibia outpatient osteotomy, using screw-to-plate locking technique and a calcium phosphate cement.

Authors:  Claude Schwartz
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-01-10

9.  Association between knee alignment and knee pain in patients surgically treated for medial knee osteoarthritis by high tibial osteotomy. A one year follow-up study.

Authors:  Annette W-Dahl; Sören Toksvig-Larsen; Ewa M Roos
Journal:  BMC Musculoskelet Disord       Date:  2009-12-08       Impact factor: 2.362

10.  [An open wedge tibial head osteotomy using continuous callus distraction. An alternative method for the treatment of of varus arthrosis].

Authors:  M H Baums; S A Esenwein; H M Klinger
Journal:  Unfallchirurg       Date:  2005-01       Impact factor: 1.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.