Literature DB >> 8472058

Peak expiratory flow monitoring and airway response to specific bronchial provocation tests in asthmatics.

G Moscato1, A Dellabianca, P Paggiaro, R Bertoletti, A Corsico, L Perfetti.   

Abstract

To assess the validity of peak expiratory flow (PEF), measured by means of a peak flow meter, in comparison to forced expiratory volume in one second (FEV1) for measuring the airway response during specific bronchial challenges, we registered PEF and FEV1 in a random sequence during 75 positive (decrease in FEV1 of > or = 15% from baseline) and 75 negative (decrease in FEV1 < 15% from baseline) challenges with chemicals or allergens. The correlation between PEF and FEV1 in terms of absolute values and of percentage of change from baseline was statistically highly significant (p < 0.001) in all challenges and in the different pattern of response, immediate, dual and late. Relative operating characteristic analysis showed that an absolute decrease in PEF of > or = 70 l.min-1 in the immediate and of > or = 80 l.min-1 in the late phase of the response (cut-off points) gave optimal discrimination between challenges with a bronchoconstrictive response (defined as a FEV1 decrease > or = 15% from baseline), and challenges without. These cut-off points, however, were highly specific (92 and 93.3%, respectively), but not as sensitive (70.6 and 61.1%, respectively), and smaller absolute changes in PEF from baseline do not exclude a bronchoconstrictive response. Our data suggest that PEF readings are a useful diagnostic tool in assessing the airway response during a specific bronchial challenge in asthmatics, although with some limitations. PEF readings can be used to monitor the late response to a challenge during the evening and the night if PEF readings are carefully considered in relation to clinical symptoms.

Mesh:

Year:  1993        PMID: 8472058

Source DB:  PubMed          Journal:  Monaldi Arch Chest Dis        ISSN: 1122-0643


  3 in total

Review 1.  Occupational lung disease. 8. The diagnosis of occupational asthma from serial measurements of lung function at and away from work.

Authors:  P Bright; P S Burge
Journal:  Thorax       Date:  1996-08       Impact factor: 9.139

Review 2.  Review of Diagnostic Challenges in Occupational Asthma.

Authors:  Jacques A Pralong; Andre Cartier
Journal:  Curr Allergy Asthma Rep       Date:  2017-01       Impact factor: 4.806

3.  Airway responses and inflammation in subjects with asthma after four days of repeated high-single-dose allergen challenge.

Authors:  Johannes Schulze; Sandra Voss; Ulrich Zissler; Markus A Rose; Stefan Zielen; Ralf Schubert
Journal:  Respir Res       Date:  2012-09-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.