Literature DB >> 8470613

Determination of cardiac ejection fraction and left ventricular volume: contrast-enhanced ultrafast cine MR imaging vs IV digital subtraction ventriculography.

K Matsumura1, E Nakase, T Haiyama, K Takeo, K Shimizu, K Yamasaki, K Kohno.   

Abstract

OBJECTIVE: To assess the accuracy of contrast-enhanced, single breath-hold cine MR imaging in the calculation of left ventricular volume and ejection fraction, we compared values obtained by using this method with those obtained by using IV digital subtraction angiography (IV-DSA). SUBJECTS AND METHODS: All patients (n = 28) had conventional cine and contrast-enhanced ultrafast cine MR imaging. For ultrafast cine MR imaging, a phase-rewind gradient-echo (rewind-SMASH) sequence was used: TR, 8 msec (standard excitation and acquisition block of 6 msec with phase rewind pulse of 2 msec); TE, 3.2 msec; a 128 x 96 matrix (pile encode factor, 6; k-space segment, 16); a 200-mm field of view; and one excitation.
RESULTS: Values for left ventricular volume and ejection fraction obtained with ultrafast cine MR imaging correlated well with those obtained with IV-DSA (end-diastolic volume, y = 0.986x - 7.79, r = .985; end-systolic volume, y = 0.863x + 0.71, r = .984; ejection fraction, y = 0.877x + 6.44, r = .887). In the calculation of left ventricular volume by the area-length method, manual tracing of the left ventricular cavity was more difficult when the conventional cine method was used than when the enhanced ultrafast cine method was used.
CONCLUSION: Our results show that cardiac multiphase study with horizontal long-axis, first-pass, contrast-enhanced, single breath-hold, cine MR imaging is an accurate and highly reproducible method of evaluating left ventricular volume and ejection fraction.

Entities:  

Mesh:

Year:  1993        PMID: 8470613     DOI: 10.2214/ajr.160.5.8470613

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

1.  Improved functional cardiac MR imaging using the intravascular contrast agent CLARISCAN.

Authors:  I Paetsch; H Thiele; B Schnackenburg; A Bornstedt; A Müller-York; J Schwab; E Fleck; E Nagel
Journal:  Int J Cardiovasc Imaging       Date:  2003-08       Impact factor: 2.357

2.  Assessment of left ventricular volumes and function by cine-MR imaging depending on the investigator's experience.

Authors:  A Bailly; J Lipiecki; P Chabrot; A Alfidja; J M Garcier; S Ughetto; J Ponsonnaille; L Boyer
Journal:  Surg Radiol Anat       Date:  2008-10-08       Impact factor: 1.246

3.  Diagnosis and therapy of ascites in liver cirrhosis.

Authors:  Erwin Biecker
Journal:  World J Gastroenterol       Date:  2011-03-14       Impact factor: 5.742

4.  Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: comparison with precontrast cine-MR sequences. Results of a bicentric study.

Authors:  Jean-Christophe Lasalarie; Jean-Michel Serfaty; Christophe Carre; David Messika-Zeitoun; Christophe Jeannot; Elisabeth Schouman-Claeys; Jean-Pierre Laissy
Journal:  Eur Radiol       Date:  2007-05-08       Impact factor: 5.315

5.  Comparison of cardiac volumetry using real-time MRI during free-breathing with standard cine MRI during breath-hold in children.

Authors:  Lena Maria Röwer; Karl Ludger Radke; Janina Hußmann; Halima Malik; Tobias Uelwer; Dirk Voit; Jens Frahm; Hans-Joerg Wittsack; Stefan Harmeling; Frank Pillekamp; Dirk Klee
Journal:  Pediatr Radiol       Date:  2022-03-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.