Effect of delay and storage on whole-blood clotting analysis as determined by thrombelastography.

C E Orlikowski1, W B Murray, D A Rocke.   

Abstract

The thrombelastogram (TEG) measures the viscoelastic properties of clotting blood, displaying a visual trace of all phases of coagulation and fibrinolysis. Thrombelastography can be performed on whole blood (WBTEG) or on citrated blood or plasma, citrated samples facilitating delayed analysis but requiring recalcification of the sample. The aim of this study was to investigate the effect of delay and storage method on WBTEG measurement. Thrombelastographic analysis of coagulation in whole blood was investigated after delays of 3 and 6 minutes in polystyrene syringes (PS3 and PS6) and 3 minutes in silicone-coated glass tubes (SG3). Thrombelastograms of the delayed samples were compared with those measured immediately. Silicone-coated glass tubes activated coagulation, as seen by shorter r times (p < 0.01), shorter r + k times (p < 0.01), and larger maximum amplitude (ma) values (p < 0.01) compared with TEG values determined immediately after sampling. In the SG3 group, 20% of samples had clotted by 3 minutes, and the use of SG tubes for this purpose cannot be recommended. A delay of 6 minutes in PS had less effect on the activation of clotting in the earlier stages in that the r time was prolonged (p < 0.01). However, there appeared to be some activation later in that k time was shorter (p < 0.01) and ma was wider (p < 0.05). Overall, a 3-minute delay in PS produced the best values.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8463805     DOI: 10.1007/bf01627630

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  6 in total

1.  Blood specimen collection tubes for coagulation tests.

Authors:  E K Blackburn; N K Shinton
Journal:  Br Med J       Date:  1979-03-31

2.  Intraoperative changes in blood coagulation and thrombelastographic monitoring in liver transplantation.

Authors:  Y G Kang; D J Martin; J Marquez; J H Lewis; F A Bontempo; B W Shaw; T E Starzl; P M Winter
Journal:  Anesth Analg       Date:  1985-09       Impact factor: 5.108

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  The use of Vacutainer tubes for collection and storage of blood for coagulation testing.

Authors:  J M Thomson; A C Easton; E B Faragher
Journal:  Clin Lab Haematol       Date:  1983

5.  Comparison of viscoelastic measures of coagulation after cardiopulmonary bypass.

Authors:  K J Tuman; B D Spiess; R J McCarthy; A D Ivankovich
Journal:  Anesth Analg       Date:  1989-07       Impact factor: 5.108

Review 6.  The thrombelastographic diagnosis of hemostatic defects.

Authors:  R C Franz; W J Coetzee
Journal:  Surg Annu       Date:  1981
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.