Construction and use of catheter-manometer systems.

P A Heimann1, W B Murray.   

Abstract

The accuracy of invasive arterial blood pressure monitoring is dependent on an adequate damped natural frequency (DNF) and damping factor (DF) of the system. Several factors influencing the DNF and DF were investigated to determine requirements for optimal design of catheter-manometer systems. The frequency sweep method was used in a specially constructed chamber that included linearizing and compensation circuitry. The DNF of isolated 20-gauge cannulae varied from 35.1 to 47.7 Hz. The DNF of 24-gauge cannulae varied from 27.7 to 44.3 Hz. An arterial cannula was found to require a DNF above 40 Hz to prevent the DNF from decreasing to below 25 Hz with the addition of arterial pressure tubing. Arterial pressure tubings exceeding 300 mm in length had DNF values that were unacceptably low even before the addition of arterial cannulae (e.g., the DNF was 23.8 Hz for a 900-mm tubing length, 19.8 Hz for 1,000-mm length, and ranged from 12.9 to 21.4 Hz for 1,200-mm lengths). The 3-way stopcocks and continuous flush devices further decreased the DNF, especially when the diameters were not matched. The percentage decrease caused by 3-way stopcocks and flush devices ranged between 19.5 and 40.8% for 300-mm length tubings and between 2.3 and 25.8% for tubings of 1,200-mm lengths. The radius ratio (outside diameter divided by inside diameter) is introduced as a new method to express the stiffness of arterial pressure tubing.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8463804     DOI: 10.1007/bf01627636

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  8 in total

1.  Physiologic recording by modern instruments with particular reference to pressure recording.

Authors:  D L FRY
Journal:  Physiol Rev       Date:  1960-10       Impact factor: 37.312

2.  Damped and undamped frequency responses of underdamped catheter manometer systems.

Authors:  G G Shapiro; L J Krovetz
Journal:  Am Heart J       Date:  1970-08       Impact factor: 4.749

3.  Measurements of pressure-wave transmission in liquid-filled tubes used for intravascular blood-pressure recording.

Authors:  K E Latimer; R D Latimer
Journal:  Med Biol Eng       Date:  1969-03

4.  Direct blood pressure measurement--dynamic response requirements.

Authors:  R M Gardner
Journal:  Anesthesiology       Date:  1981-03       Impact factor: 7.892

5.  The frequency response of external transducer blood pressure measurement systems: a theoretical and experimental study.

Authors:  C W Yeomanson; D H Evans
Journal:  Clin Phys Physiol Meas       Date:  1983-11

6.  Measurement of the volume displacement of blood-pressure transducers.

Authors:  L A Geddes; W Athens; S Aronson
Journal:  Med Biol Eng Comput       Date:  1984-11       Impact factor: 2.602

Review 7.  Comparison of direct and indirect measuring arterial blood pressure.

Authors:  J M Bruner; L J Krenis; J M Kunsman; A P Sherman
Journal:  Med Instrum       Date:  1981 Jan-Feb

8.  Practical evaluation of catheter-transducer coupling systems for artifact.

Authors:  G S Miller; J P Zbilut
Journal:  Heart Lung       Date:  1983-03       Impact factor: 2.210

  8 in total
  1 in total

1.  Estimation of cardiac output in a pharmacological trial using a simple method based on arterial blood pressure signal waveform: a comparison with pulmonary thermodilution and echocardiographic methods.

Authors:  Jani Penttilä; Amir Snapir; Erkki Kentala; Juha Koskenvuo; Jussi Posti; Mika Scheinin; Harry Scheinin; Tom Kuusela
Journal:  Eur J Clin Pharmacol       Date:  2006-03-29       Impact factor: 2.953

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.