The Johnson antishear device and standard shin pad in the isokinetic assessment of the knee.

C K Li1, K M Chan, S Y Hsu, P Chien, M W Wong, Y Yuan.   

Abstract

Isokinetic training and assessment of the knee joint has been the mainstay of rehabilitation, especially in patients with anterior cruciate ligament deficiency. Besides the original shin pad used, the antishear device was introduced by Johnson in 1982. This device has been shown biomechanically to prevent excessive anterior translation of force on the tibia during training. However, there is a need to compare the antishear device and the standard shin pad in the isokinetic assessment. Hence, the major objective of this study is to define, if any, the difference in patient assessment between the new double pad device and the old single shin pad. Ten subjects with no previous history of injury on either knee were tested with the Cybex Isokinetic Dynamometer. There were four men and six women and the mean age was 25.2 years. They were randomized into different test sequences with different shin pads at different speeds. Correlation and paired t tests (P) were performed to find out the correlation and difference between the two devices. There was significant difference in performance assessment between the two devices in knee extension (P < 0.05) but no significant difference in knee flexion (P > 0.05). There was also a high correlation (r > 0.75) between the two devices. It is concluded that because of the significant difference of data generated between the two devices, it is important to select one single device with each patient during a series of testings.

Entities:  

Mesh:

Year:  1993        PMID: 8457814      PMCID: PMC1332108          DOI: 10.1136/bjsm.27.1.49

Source DB:  PubMed          Journal:  Br J Sports Med        ISSN: 0306-3674            Impact factor:   13.800


  1 in total

1.  Tibiofemoral joint forces during isokinetic knee extension.

Authors:  R Nisell; M O Ericson; G Németh; J Ekholm
Journal:  Am J Sports Med       Date:  1989 Jan-Feb       Impact factor: 6.202

  1 in total
  2 in total

1.  A quantifiable approach in the comparison of isokinetic assessment data--new correlation equations for the Johnson antishear device and standard shin pad in the isokinetic assessment of the knee.

Authors:  C K Li; K M Chan; Y S Hsu; P Chien; W N Wong
Journal:  Br J Sports Med       Date:  1995-09       Impact factor: 13.800

2.  Effect of subject restraint and resistance pad placement on isokinetic knee flexor and extensor strength: implications for testing and rehabilitation.

Authors:  Roald Otten; Rod Whiteley; Tim Mitchell
Journal:  Sports Health       Date:  2013-03       Impact factor: 3.843

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.