Literature DB >> 8456530

Histological changes in rat liver tumours treated with high-intensity focused ultrasound.

L Chen1, I Rivens, G ter Haar, S Riddler, C R Hill, J P Bensted.   

Abstract

This paper reports the histological changes found in rat liver tumours treated with high-intensity focused ultrasound. HSN fibrosarcoma, implanted subcapsularly in the livers of CBH rats, were treated using an array of ultrasound exposures. At predetermined times following treatment, the rats were sacrificed and tissue specimens were examined histologically. Evident tissue damage was confined to regions that had been given high ultrasound exposures. Within these regions ("lesions") there was no evidence of intact cells whereas in the sharply demarcated surrounding tissue there was no evidence of cell damage. Where individual ultrasound lesions had been placed in sufficiently close proximity, there was correspondingly continuous and complete cell destruction. There is suggestive evidence that tissue damage may arise through two different mechanisms: direct, primarily thermal, damage and indirect damage resulting from compromised blood supply. Under the same exposure conditions, normal liver cells appear to lose their morphological structure more readily than do tumour cells.

Entities:  

Mesh:

Year:  1993        PMID: 8456530     DOI: 10.1016/0301-5629(93)90019-k

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  19 in total

1.  Pulsatile flow phantom for ultrasound image-guided HIFU treatment of vascular injuries.

Authors:  Robyn Greaby; Vesna Zderic; Shahram Vaezy
Journal:  Ultrasound Med Biol       Date:  2007-04-27       Impact factor: 2.998

2.  Complications of high intensity focused ultrasound in patients with recurrent and metastatic abdominal tumors.

Authors:  Jian-Jun Li; Guo-Liang Xu; Mo-Fa Gu; Guang-Yu Luo; Zhang Rong; Pei-Hong Wu; Jian-Chuan Xia
Journal:  World J Gastroenterol       Date:  2007-05-21       Impact factor: 5.742

Review 3.  MR-guided focused ultrasound surgery, present and future.

Authors:  David Schlesinger; Stanley Benedict; Chris Diederich; Wladyslaw Gedroyc; Alexander Klibanov; James Larner
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

4.  Sequential changes in rat femoral artery blood flow and tissue degeneration after exposure to high-intensity focused ultrasound.

Authors:  Tetsuya Ishikawa; Takashi Okai; Kazuaki Sasaki; Shin-Ichiro Umemura; Nozomi Miyazaki; Miki Kushima; Hiroko Aoki; Mitsuyoshi Ichihara; Kiyotake Ichizuka
Journal:  J Med Ultrason (2001)       Date:  2008-12-16       Impact factor: 1.314

5.  High-intensity focused ultrasound induced apoptosis with caspase 3, 8, and 9/6 activation in rat hepatoma.

Authors:  Naoki Hirokawa; Kazumitsu Koito; Futoshi Okada; Nobuki Kudo; Katsuyuki Yamamoto; Katsuhiko Fujimoto; Mutsumi Nishida; Takeshi Ichimura; Masakazu Hori; Taishi Satoh; Masato Hareyama
Journal:  J Med Ultrason (2001)       Date:  2009-09-04       Impact factor: 1.314

6.  High-intensity focused ultrasound ablation: an effective and safe treatment for secondary hypersplenism.

Authors:  J Zhu; H Zhu; Z Mei; L Zhang; C Jin; L Ran; K Zhou; W Yang
Journal:  Br J Radiol       Date:  2014-08-20       Impact factor: 3.039

Review 7.  Sound waves and antineoplastic drugs: The possibility of an enhanced combined anticancer therapy.

Authors:  Loreto B Feril; Takashi Kondo; Shin-Ichiro Umemura; Katsuro Tachibana; Angelo H Manalo; Peter Riesz
Journal:  J Med Ultrason (2001)       Date:  2002-12       Impact factor: 1.314

8.  Multi-parametric monitoring and assessment of high-intensity focused ultrasound (HIFU) boiling by harmonic motion imaging for focused ultrasound (HMIFU): an ex vivo feasibility study.

Authors:  Gary Y Hou; Fabrice Marquet; Shutao Wang; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

9.  Short-duration-focused ultrasound stimulation of Hsp70 expression in vivo.

Authors:  D E Kruse; M A Mackanos; C E O'Connell-Rodwell; C H Contag; K W Ferrara
Journal:  Phys Med Biol       Date:  2008-06-19       Impact factor: 3.609

Review 10.  Balloon catheters for pulmonary vein isolation.

Authors:  Boris Schmidt; Kyoung Ryul Julian Chun; Andreas Metzner; Feifan Ouyang; Karl-Heinz Kuck
Journal:  Herz       Date:  2008-12       Impact factor: 1.443

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.