Correction of intensity nonuniformity in MR images of any orientation.

D A Wicks1, G J Barker, P S Tofts.   

Abstract

The specialised radiofrequency (RF) coils used in MRI such as head or surface coils can give rise to marked image intensity nonuniformities. There are two situations in which it is essential to correct this: (1) When a global intensity threshold is used to segment particular tissues; and (2) in proton density images, from which the proton concentration can be measured provided that the system gain is uniform or known over the whole image. We describe experiments to determine the magnitude and sources of nonuniformity in a 0.5-T system, and assess methods devised to correct for them in scans of any orientation, including oblique scans at arbitrary angles to the magnet axis and arbitrary offsets from the magnet iso-centre. A correction based on the response of a system to a uniform phantom was implemented. Tests of the correction with orthogonal views demonstrate that the uniformity of images of any orientation can be improved significantly with a correction matrix from just one orientation and still further with two matrices, one axial and the other either coronal or sagittal. We expect further improvements to be possible if gradient coil eddy current effects can be reduced.

Mesh:

Year:  1993        PMID: 8455430     DOI: 10.1016/0730-725x(93)90023-7

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  20 in total

1.  Rapid and effective correction of RF inhomogeneity for high field magnetic resonance imaging.

Authors:  M S Cohen; R M DuBois; M M Zeineh
Journal:  Hum Brain Mapp       Date:  2000-08       Impact factor: 5.038

2.  Arterial spin labeling at 3.0 Tesla in subacute ischemia: comparison to dynamic susceptibility perfusion.

Authors:  S Huck; H U Kerl; M Al-Zghloul; C Groden; I Nölte
Journal:  Clin Neuroradiol       Date:  2012-01-20       Impact factor: 3.649

3.  Survey of the distribution of lesion size in multiple sclerosis: implication for the measurement of total lesion load.

Authors:  L Wang; H M Lai; A J Thompson; D H Miller
Journal:  J Neurol Neurosurg Psychiatry       Date:  1997-10       Impact factor: 10.154

4.  MR imaging of the cervical spine: assessment of image quality with parallel imaging compared to non-accelerated MR measurements.

Authors:  Iris-M Noebauer-Huhmann; Christian Glaser; Olaf Dietrich; Claus-Peter Wallner; Wolfgang Klinger; Herwig Imhof; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

5.  MRI of degenerative lumbar spine disease: comparison of non-accelerated and parallel imaging.

Authors:  Ingo Nölte; Lars Gerigk; Marc A Brockmann; André Kemmling; Christoph Groden
Journal:  Neuroradiology       Date:  2008-05       Impact factor: 2.804

6.  Long-term reproducibility of phantom signal intensities in nonuniformity corrected STIR-MRI examinations of skeletal muscle.

Authors:  Alain R Viddeleer; Paul E Sijens; Peter M A van Ooijen; Paul D L Kuypers; Steven E R Hovius; Matthijs Oudkerk
Journal:  MAGMA       Date:  2009-02-24       Impact factor: 2.310

7.  Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient-recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequences.

Authors:  T Meindl; S Wirth; S Weckbach; O Dietrich; M Reiser; S O Schoenberg
Journal:  Eur Radiol       Date:  2008-09-24       Impact factor: 5.315

8.  A method of RF inhomogeneity correction in MR imaging.

Authors:  H Mihara; N Iriguchi; S Ueno
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

9.  MRI lesion volume measurement in multiple sclerosis and its correlation with disability: a comparison of fast fluid attenuated inversion recovery (fFLAIR) and spin echo sequences.

Authors:  M L Gawne-Cain; J I O'Riordan; A Coles; B Newell; A J Thompson; D H Miller
Journal:  J Neurol Neurosurg Psychiatry       Date:  1998-02       Impact factor: 10.154

10.  A modified method for MRF segmentation and bias correction of MR image with intensity inhomogeneity.

Authors:  Mei Xie; Jingjing Gao; Chongjin Zhu; Yan Zhou
Journal:  Med Biol Eng Comput       Date:  2014-10-11       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.