Literature DB >> 8450743

Consistent projection reconstruction (CPR) techniques for MRI.

G H Glover1, D C Noll.   

Abstract

Motion of the subject causes inconsistencies in MR scan data which in turn produce streaks in projection reconstruction (PR) scans or ghosts in 2DFT imaging. It is shown that a data manifold consistent with a static object may be extracted from input scan data by applying consistency criteria based on moment or Fourier expansions of the object's projections. The criteria limit the spectrum of azimuthal variation relative to the radial moments or radial spectral components, and their application diminishes k-space inconsistencies from motion or flow by discarding unallowed expansion terms. This consistent projection reconstruction (CPR) algorithm was applied to the reconstruction of projection data from a moving phantom and from human abdominal sections, and in each case provided reduced motion streaks relative to conventional reconstructions. In addition, CPR was found to be effective when used with 2DFT data by resampling the Cartesian data as radial projections, but to a lesser extent.

Entities:  

Mesh:

Year:  1993        PMID: 8450743     DOI: 10.1002/mrm.1910290310

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  MR image reconstruction algorithms for sparse k-space data: a Java-based integration.

Authors:  R de Beer; A Coron; D Graveron-Demilly; R Lethmate; S Nastase; D van Ormondt; F T A W Wajer
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

2.  Advantages of radial volumetric breath-hold examination (VIBE) with k-space weighted image contrast reconstruction (KWIC) over Cartesian VIBE in liver imaging of volunteers simulating inadequate or no breath-holding ability.

Authors:  Yasunari Fujinaga; Yoshihiro Kitou; Ayumi Ohya; Yasuo Adachi; Naomichi Tamaru; Aya Shiobara; Hitoshi Ueda; Marcel D Nickel; Katsuya Maruyama; Masumi Kadoya
Journal:  Eur Radiol       Date:  2015-11-24       Impact factor: 5.315

3.  Free-breathing dynamic contrast-enhanced MRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC).

Authors:  Kyung Won Kim; Jeong Min Lee; Yong Sik Jeon; Sung Eun Kang; Jee Hyun Baek; Joon Koo Han; Byung Ihn Choi; Yung-Jue Bang; Berthold Kiefer; Kai Tobias Block; Hyunjun Ji; Simon Bauer; Chin Kim
Journal:  Eur Radiol       Date:  2012-11-28       Impact factor: 5.315

4.  Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase.

Authors:  Yasunari Fujinaga; Ayumi Ohya; Hirokazu Tokoro; Akira Yamada; Kazuhiko Ueda; Hitoshi Ueda; Yoshihiro Kitou; Yasuo Adachi; Aya Shiobara; Naomichi Tamaru; Marcel D Nickel; Katsuya Maruyama; Masumi Kadoya
Journal:  Eur Radiol       Date:  2014-03-15       Impact factor: 5.315

5.  Adaptive retrospective correction of motion artifacts in cranial MRI with multicoil three-dimensional radial acquisitions.

Authors:  Ashley G Anderson; Julia Velikina; Walter Block; Oliver Wieben; Alexey Samsonov
Journal:  Magn Reson Med       Date:  2012-07-03       Impact factor: 4.668

6.  Respiratory motion-compensated radial dynamic contrast-enhanced (DCE)-MRI of chest and abdominal lesions.

Authors:  Wei Lin; Junyu Guo; Mark A Rosen; Hee Kwon Song
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

7.  Acceleration and motion-correction techniques for high-resolution intravascular MRI.

Authors:  Shashank Sathyanarayana Hegde; Yi Zhang; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2014-08-27       Impact factor: 4.668

8.  Prospective head-movement correction for high-resolution MRI using an in-bore optical tracking system.

Authors:  Lei Qin; Peter van Gelderen; John Andrew Derbyshire; Fenghua Jin; Jongho Lee; Jacco A de Zwart; Yang Tao; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

9.  Adapted random sampling patterns for accelerated MRI.

Authors:  Florian Knoll; Christian Clason; Clemens Diwoky; Rudolf Stollberger
Journal:  MAGMA       Date:  2011-01-07       Impact factor: 2.310

Review 10.  Cardiovascular magnetic resonance artefacts.

Authors:  Pedro F Ferreira; Peter D Gatehouse; Raad H Mohiaddin; David N Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2013-05-22       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.