Literature DB >> 8450338

LINAC radiosurgery: an animal model.

R Spiegelmann1, W A Friedman, F J Bova, D P Theele, J P Mickle.   

Abstract

Fifteen cats were irradiated with an animal LINAC (linear accelerator) radiosurgery device. After 6 months, they were studied with gadolinium-enhanced magnetic resonance (MR) imaging, gross pathology after Evans blue perfusion, and histopathology. The lesion size was relatively constant in the cats receiving a dose of 7500, 10,000, 12,500, or 15,000 cGy to the 84% isodose line of a 1-cm collimator. The composition of the lesion correlated with dose: the lower-dose lesions were found histologically to contain areas of edema, demyelination, reactive gliosis, and vascular proliferation; the higher-dose lesions contained increasing amounts of hemorrhage and coagulative necrosis. The borders of the lesions were sharply demarcated from surrounding normal brain. Gadolinium-enhanced MR studies correlated well with areas of blood-brain barrier breakdown, as confirmed by areas of Evans blue staining. This model could serve as the basis for further studies of the biological effects of LINAC radiosurgery.

Entities:  

Mesh:

Year:  1993        PMID: 8450338     DOI: 10.3171/jns.1993.78.4.0638

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  5 in total

1.  Development of a novel animal model to differentiate radiation necrosis from tumor recurrence.

Authors:  Sanath Kumar; Ali S Arbab; Rajan Jain; Jinkoo Kim; Ana C deCarvalho; Adarsh Shankar; Tom Mikkelsen; Stephen L Brown
Journal:  J Neurooncol       Date:  2012-03-10       Impact factor: 4.130

2.  Differentiation of recurrent glioblastoma multiforme from radiation necrosis after external beam radiation therapy with dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging.

Authors:  Ramon F Barajas; Jamie S Chang; Mark R Segal; Andrew T Parsa; Michael W McDermott; Mitchel S Berger; Soonmee Cha
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

3.  Specific issues in small animal dosimetry and irradiator calibration.

Authors:  Terry Yoshizumi; Samuel L Brady; Mike E Robbins; J Daniel Bourland
Journal:  Int J Radiat Biol       Date:  2011-10       Impact factor: 2.694

4.  Study logistics that can impact medical countermeasure efficacy testing in mouse models of radiation injury.

Authors:  Andrea L DiCarlo; Zulmarie Perez Horta; Carmen I Rios; Merriline M Satyamitra; Lanyn P Taliaferro; David R Cassatt
Journal:  Int J Radiat Biol       Date:  2020-09-24       Impact factor: 2.694

5.  True progression versus pseudoprogression in the treatment of glioblastomas: a comparison study of normalized cerebral blood volume and apparent diffusion coefficient by histogram analysis.

Authors:  Yong Sub Song; Seung Hong Choi; Chul-Kee Park; Kyung Sik Yi; Woong Jae Lee; Tae Jin Yun; Tae Min Kim; Se-Hoon Lee; Ji-Hoon Kim; Chul-Ho Sohn; Sung-Hye Park; Il Han Kim; Geon-Ho Jahng; Kee-Hyun Chang
Journal:  Korean J Radiol       Date:  2013-07-17       Impact factor: 3.500