Dosing efficiency and particle-size characteristics of pressurized metered-dose inhaler aerosols in narrow catheters.

R H Taylor1, J Lerman, C Chambers, M Dolovich.   

Abstract

An experimental in vitro model was used to determine the effects of intraluminal catheter diameter and length on the delivered dose and particle-size characteristics of salbutamol (albuterol) aerosol delivered by metered dose inhaler (MDI) (Ventolin, 100 micrograms per puff). The dose of aerosolized drug that exited a 16-cm-long tracheal tube with an inner diameter (ID) of 6 mm was compared with that from 4 catheters of differing diameters and lengths that were inserted individually into the tracheal tube. The salbutamol MDI canister was actuated ten times into each delivery system, and the effluent aerosol was trapped onto a filter. The filtrate was dissolved in methanol, and the salbutamol concentration was determined using high-performance liquid chromatography. For the 3 22-cm-long catheters, the delivered dose (mean +/- SD) of salbutamol per actuation for the 22-standard wire gauge (SWG) catheter was 97.5 +/- 3.9 micrograms, which was similar to that for the 19-SWG catheter (102.3 +/- 2.5 micrograms) but was significantly less than that for the 14-SWG catheter (108.2 +/- 4.2 micrograms) (p < 0.05). These delivered doses exceeded those of the 6.0-mm-ID tracheal tube alone (2.33 +/- 0.76 micrograms) and the 13-cm-long 19-SWG catheter (2.17 +/- 0.29 micrograms) (p < 0.001). In a second experiment using a cascade impactor, the distribution of aerosol particle diameters that exited the 6-mm-ID tracheal tube was compared with that exiting a 13-cm-long 19-SWG catheter that extended halfway down the tracheal tube and with that exiting a 22-cm-long 19-SWG catheter inserted into the distal end of the 6-mm-ID tracheal tube. The mass median aerodynamic diameter (mean +/- SD) of the salbutamol aerosols delivered through both the 6.0-mm-ID tracheal tube (1.1 +/- 0.1 microns) and that of the 13-cm-long 19-SWG catheter (1.2 +/- 0.2 microns) were significantly less than that delivered through the 22-cm-long 19-SWG catheter (2.0 +/- 0.1 microns) (p < 0.05). The authors conclude that delivery of respirable aerosol can occur through narrow catheters that function as extended nozzles for MDIs. Optimal dosing will be obtained when the catheter extends the full length of the tracheal tube.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8449093     DOI: 10.1378/chest.103.3.920

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  5 in total

1.  In vitro assessment of drug delivery through an endotracheal tube using a dry powder inhaler delivery system.

Authors:  M L Everard; S G Devadason; P N Le Souëf
Journal:  Thorax       Date:  1996-01       Impact factor: 9.139

2.  Preliminary study of electrocautery smoke particles produced in vitro and during laparoscopic procedures.

Authors:  J G DesCoteaux; P Picard; E C Poulin; M Baril
Journal:  Surg Endosc       Date:  1996-02       Impact factor: 4.584

Review 3.  RNAi therapeutic strategies for acute respiratory distress syndrome.

Authors:  Melissa L Jagrosse; David A Dean; Arshad Rahman; Bradley L Nilsson
Journal:  Transl Res       Date:  2019-07-27       Impact factor: 7.012

4.  VACuum INtubation (VACcIN) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype.

Authors:  Rami Issa; Robert Urbanowicz; Philippe Richebé; Julie Blain; Alexandre Ferreira Benevides; Issam Tanoubi
Journal:  J Clin Monit Comput       Date:  2021-09-25       Impact factor: 1.977

Review 5.  The delivery of aerosolized steroids from MDIs with nozzle extensions: quantitative laboratory evaluation of a method to improve aerosol delivery to intubated patients.

Authors:  D Hess; D Fisher; R A Peterfreund; R M Kacmarek
Journal:  Intensive Care Med       Date:  1995-11       Impact factor: 17.440

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.