Literature DB >> 8442817

Pull-out strength of five suture anchors.

J E Carpenter1, D N Fish, L J Huston, S A Goldstein.   

Abstract

Five commercially available suture anchor devices were tested to failure in human cadaveric proximal tibiae. A total of 198 trials were completed. Insertion was uncomplicated for all anchors, with the exception of the Acufex Rod TAG device, with five of 22 (23%) of these breaking upon insertion into thicker cortical bone. Overall, the anchors performed significantly (p < 0.05) better when placed in thicker cortical bone, further away from the joint surface, and when loaded in a direction parallel to the bone surface. The Mitek GII anchor failed (pulled out of bone) less often than the other anchors (19% vs. 46%). In loading perpendicular to the bone surface, the Mitek GII and Statak were the strongest (p < 0.05), with mean loads at failure of 82.5 and 90.2 N, respectively. The Acufex Rod TAG, Acufex Wedge TAG, and Mitek GI failed at 67.2, 65.5, and 49.4 N respectively.

Entities:  

Mesh:

Year:  1993        PMID: 8442817     DOI: 10.1016/s0749-8063(05)80354-8

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  7 in total

1.  Repair of collateral ligament instability in 2 foals by using suture anchors.

Authors:  D H Rodgerson; M A Spirito
Journal:  Can Vet J       Date:  2001-07       Impact factor: 1.008

2.  The effect of two nonresorbable suture types on the mechanical performance over a metal suture anchor eyelet.

Authors:  D Acton; A Perry; R Evans; A Butler; P Stephens; W Bruce; J Goldberg; D Sonnabend; W R Walsh
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-09-12       Impact factor: 4.342

3.  A novel technique of lumbar hernia repair using bone anchor fixation.

Authors:  A M Carbonell; K W Kercher; L Sigmon; B D Matthews; R F Sing; J S Kneisl; B T Heniford
Journal:  Hernia       Date:  2004-09-10       Impact factor: 4.739

4.  Recurrent acute hemarthrosis after anterior cruciate ligament reconstruction. Report of an unusual complication and a review of the literature.

Authors:  N F Friederich; S Czaja
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1996       Impact factor: 4.342

5.  Fixation methods and implants in shoulder stabilization: A historical perspective.

Authors:  Jonathan D Kramer; Sean Robinson; Eric Hohn; Connor Purviance; Eugene M Wolf
Journal:  J Orthop       Date:  2018-05-07

6.  Extensor carpi radialis longus and brevis rupture in a boxer.

Authors:  T Mundell; N Miladore; T Ruiter
Journal:  Eplasty       Date:  2014-10-21

7.  Laparoscopic repair of incisional and other complex abdominal wall hernias.

Authors:  Randall O Craft; Kristi L Harold
Journal:  Perm J       Date:  2009
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.