In vitro hematological testing of rotary blood pumps: remarks on standardization and data interpretation.

M R Mueller1, H Schima, H Engelhardt, A Salat, D B Olsen, U Losert, E Wolner.   

Abstract

Pump test procedures using blood will have to meet several standards not only to obtain reliable results in vitro but also to allow comparison of results of different investigators. This article reviews some of the issues that should be considered in pump testing, especially referring to the discussions held at the International Workshops on Rotary Blood Pumps in 1988 and 1991. The test loop itself should meet some requirements such as constant physiological temperature, standardized circulating volume, control of pressure and flow, and exact definition of the blood-contacting surface. Specifications have to be made concerning the test fluid blood, including sampling technique, anticoagulation, blood gases, pH, and glucose level. Only fresh blood should be used. Heparin is recommended for anticoagulation because it will be used also in vivo. Different procedures for cleaning and rinsing of plastic materials for reuse are mentioned. Bacterial overgrowth, which can lead to extreme oxygen consumption and acidosis, may be avoided through addition of antibiotics (e.g., gentamicin). To be able to compare data of the different working groups, a new modified index of hemolysis (MIH) has been defined.

Entities:  

Mesh:

Year:  1993        PMID: 8439269     DOI: 10.1111/j.1525-1594.1993.tb00419.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  Multilaboratory study of flow-induced hemolysis using the FDA benchmark nozzle model.

Authors:  Luke H Herbertson; Salim E Olia; Amanda Daly; Christopher P Noatch; William A Smith; Marina V Kameneva; Richard A Malinauskas
Journal:  Artif Organs       Date:  2014-09-02       Impact factor: 3.094

2.  Durability improvement of polymer chamber of pulsatile extracorporeal life support system in terms of mechanical change.

Authors:  Hyuk Choi; Seung Hoon Paik; Kwang Ho Lee; Byoung Goo Min; Yong Soon Won
Journal:  Med Biol Eng Comput       Date:  2007-08-25       Impact factor: 3.079

3.  Validation of a Miniaturized Test Loop for the Assessment of Human Blood Damage by Continuous-Flow Left-Ventricular Assist Devices.

Authors:  Eva Woelke; Ilona Mager; Thomas Schmitz-Rode; Ulrich Steinseifer; Johanna C Clauser
Journal:  Ann Biomed Eng       Date:  2021-08-24       Impact factor: 3.934

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.