Literature DB >> 8439150

Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling.

M P Buttner1, L D Stetzenbach.   

Abstract

Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8439150      PMCID: PMC202081          DOI: 10.1128/aem.59.1.219-226.1993

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  17 in total

1.  Comparison of bioaerosol sampling methods in barns housing swine.

Authors:  P S Thorne; M S Kiekhaefer; P Whitten; K J Donham
Journal:  Appl Environ Microbiol       Date:  1992-08       Impact factor: 4.792

2.  Inhaled endotoxin and decreased spirometric values. An exposure-response relation for cotton dust.

Authors:  R M Castellan; S A Olenchock; K B Kinsley; J L Hankinson
Journal:  N Engl J Med       Date:  1987-09-03       Impact factor: 91.245

3.  Hospital airborne bacteria as estimated by the Andersen sampler versus the gravity settling culture plate.

Authors:  W J Sayer; N M MacKnight; H W Wilson
Journal:  Am J Clin Pathol       Date:  1972-11       Impact factor: 2.493

4.  Performance of the surface air system air samplers.

Authors:  V Lach
Journal:  J Hosp Infect       Date:  1985-03       Impact factor: 3.926

5.  Outbreak of hypersensitivity pneumonitis in an industrial setting.

Authors:  E D Woodard; B Friedlander; R J Lesher; W Font; R Kinsey; F T Hearne
Journal:  JAMA       Date:  1988-04-01       Impact factor: 56.272

6.  Bacterial endotoxin isolated from a water spray air humidification system as a putative agent of occupation-related lung disease.

Authors:  D K Flaherty; F H Deck; J Cooper; K Bishop; P A Winzenburger; L R Smith; L Bynum; W B Witmer
Journal:  Infect Immun       Date:  1984-01       Impact factor: 3.441

7.  Fungi as a cause of allergic disease.

Authors:  S Gravesen
Journal:  Allergy       Date:  1979-06       Impact factor: 13.146

8.  Aerosols containing Legionella pneumophila generated by shower heads and hot-water faucets.

Authors:  G E Bollin; J F Plouffe; M F Para; B Hackman
Journal:  Appl Environ Microbiol       Date:  1985-11       Impact factor: 4.792

9.  Trichothecene mycotoxins in aerosolized conidia of Stachybotrys atra.

Authors:  W G Sorenson; D G Frazer; B B Jarvis; J Simpson; V A Robinson
Journal:  Appl Environ Microbiol       Date:  1987-06       Impact factor: 4.792

Review 10.  Occurrence of moulds in modern living and working environments.

Authors:  R A Samson
Journal:  Eur J Epidemiol       Date:  1985-03       Impact factor: 8.082

View more
  23 in total

1.  Evaluation of three portable samplers for monitoring airborne fungi.

Authors:  S K Mehta; S K Mishra; D L Pierson
Journal:  Appl Environ Microbiol       Date:  1996-05       Impact factor: 4.792

2.  Enhanced detection of surface-associated bacteria in indoor environments by quantitative PCR.

Authors:  M P Buttner; P Cruz-Perez; L D Stetzenbach
Journal:  Appl Environ Microbiol       Date:  2001-06       Impact factor: 4.792

Review 3.  Atmospheric movement of microorganisms in clouds of desert dust and implications for human health.

Authors:  Dale W Griffin
Journal:  Clin Microbiol Rev       Date:  2007-07       Impact factor: 26.132

4.  Impaction onto a Glass Slide or Agar versus Impingement into a Liquid for the Collection and Recovery of Airborne Microorganisms.

Authors:  A Juozaitis; K Willeke; S A Grinshpun; J Donnelly
Journal:  Appl Environ Microbiol       Date:  1994-03       Impact factor: 4.792

5.  Airborne fungal colony-forming units in outdoor and indoor environments in Yokohama, Japan.

Authors:  T Takahashi
Journal:  Mycopathologia       Date:  1997       Impact factor: 2.574

6.  Field sampling of indoor bioaerosols.

Authors:  Jennie Cox; Hamza Mbareche; William G Lindsley; Caroline Duchaine
Journal:  Aerosol Sci Technol       Date:  2019-11-21       Impact factor: 2.908

7.  Visually observed mold and moldy odor versus quantitatively measured microbial exposure in homes.

Authors:  Tiina Reponen; Umesh Singh; Chris Schaffer; Stephen Vesper; Elisabet Johansson; Atin Adhikari; Sergey A Grinshpun; Reshmi Indugula; Patrick Ryan; Linda Levin; Grace Lemasters
Journal:  Sci Total Environ       Date:  2010-10-15       Impact factor: 7.963

8.  Evaluation of the Biological Sampling Kit (BiSKit) for large-area surface sampling.

Authors:  Mark P Buttner; Patricia Cruz; Linda D Stetzenbach; Amy K Klima-Comba; Vanessa L Stevens; Peter A Emanuel
Journal:  Appl Environ Microbiol       Date:  2004-12       Impact factor: 4.792

9.  Airborne fungal load in agricultural environment during threshing operations.

Authors:  N Uddin; R Chakraverty
Journal:  Mycopathologia       Date:  1994-09       Impact factor: 2.574

10.  Determination of the efficacy of two building decontamination strategies by surface sampling with culture and quantitative PCR analysis.

Authors:  Mark P Buttner; Patricia Cruz; Linda D Stetzenbach; Amy K Klima-Comba; Vanessa L Stevens; Tracy D Cronin
Journal:  Appl Environ Microbiol       Date:  2004-08       Impact factor: 4.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.