Literature DB >> 8435256

Use of ultrasound to evaluate internal jugular vein anatomy and to facilitate central venous cannulation in paediatric patients.

P J Alderson1, F A Burrows, L I Stemp, H M Holtby.   

Abstract

Percutaneous cannulation of the internal jugular vein in paediatric patients may be technically difficult and is prone to complications. To investigate the possibility that anatomical factors contribute to these difficulties, we used a two-dimensional ultrasound scanner to examine venous anatomy in children aged up to 6 yr. We found that 18% of our children had anomalous venous anatomy that may account for some of the difficulties reported previously. The diameter of the internal jugular vein was predicted poorly by the patient's age (r2 = 0.259) or weight (r2 = 0.155). We also evaluated the use of this ultrasound scanner during percutaneous central venous cannulation in neonates and infants. Determining the course of the internal jugular vein with the scanner and then marking it on the overlying skin reduced both the time and number of needle insertions required to aspirate jugular venous blood and increased the chance of a complication-free cannulation.

Entities:  

Mesh:

Year:  1993        PMID: 8435256     DOI: 10.1093/bja/70.2.145

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  31 in total

1.  Inadvertent intrathecal cannulation in an infant, demonstrated by three-dimensional computed tomography: a rare complication of internal jugular vein catheterization.

Authors:  Yoshihito Fujita; Kazuya Sobue; Tomonori Hattori; Akinori Takeuchi; Takako Tsuda; Hirotada Katsuya
Journal:  J Anesth       Date:  2006       Impact factor: 2.078

2.  Skin-traction method prevents the collapse of the internal jugular vein caused by an ultrasound probe in real-time ultrasound-assisted guidance.

Authors:  Hiroshi Sasano; Masato Morita; Takafumi Azami; Shoji Ito; Nobuko Sasano; Rina Kato; Hiroyuki Hirate; Hiroaki Ito; Akinori Takeuchi; Kazuya Sobue
Journal:  J Anesth       Date:  2009-02-22       Impact factor: 2.078

3.  Ultrasound-guided internal jugular vein catheterization in critically ill pediatric patients.

Authors:  Eu Jeen Yang; Hyeong Seok Ha; Young Hwa Kong; Sun Jun Kim
Journal:  Korean J Pediatr       Date:  2015-04-22

Review 4.  Ultrasound-guided central vascular interventions, comments on the European Federation of Societies for Ultrasound in Medicine and Biology guidelines on interventional ultrasound.

Authors:  Christoph F Dietrich; Rudolf Horn; Susanne Morf; Liliana Chiorean; Yi Dong; Xin-Wu Cui; Nathan S S Atkinson; Christian Jenssen
Journal:  J Thorac Dis       Date:  2016-09       Impact factor: 2.895

Review 5.  Anesthesiological and intensive care considerations in children undergoing extensive cerebral excision procedure for congenital epileptogenic lesions.

Authors:  D Pietrini; F Zanghi; A Pusateri; F Tosi; S Pulitanò; M Piastra
Journal:  Childs Nerv Syst       Date:  2006-06-29       Impact factor: 1.475

6.  Vascular ultrasound in pediatrics: utility and application of location and measurement of jugular and femoral vessels.

Authors:  J M López Álvarez; O Pérez Quevedo; L Santana Cabrera; C Rodríguez Escot; T Ramírez Lorenzo; J M Limiñana Cañal; J F Loro Ferrer
Journal:  J Med Ultrason (2001)       Date:  2017-12-18       Impact factor: 1.314

Review 7.  Bedside ultrasound in pediatric critical care: a review.

Authors:  Sushant Srinivasan; Timothy T Cornell
Journal:  Pediatr Crit Care Med       Date:  2011-11       Impact factor: 3.624

8.  Ultrasound-guided percutaneous insertion of 2.7 Fr tunnelled Broviac lines in neonates and small infants.

Authors:  G S Arul; H Livingstone; P Bromley; J Bennett
Journal:  Pediatr Surg Int       Date:  2010-06-13       Impact factor: 1.827

9.  [Ultrasound-guided central venous access in adults and children: Procedure and pathological findings].

Authors:  P Scheiermann; F H Seeger; R Breitkreutz
Journal:  Anaesthesist       Date:  2010-01       Impact factor: 1.041

Review 10.  [Central venous catheter for newborns, infants and children].

Authors:  C Breschan; M Platzer; R Likar
Journal:  Anaesthesist       Date:  2009-09       Impact factor: 1.041

View more