Literature DB >> 8429055

Natural preload of aortic valve leaflet components during glutaraldehyde fixation: effects on tissue mechanics.

I Vesely1, A Lozon.   

Abstract

The mechanics of glutaraldehyde-fixed aortic valve leaflets depend largely on the amount of stress present during fixation. Our previous work has suggested that even when the aortic valve is flaccid, the leaflet components are preloaded. We have, therefore, hypothesized that fixing valve leaflets in this naturally preloaded state will affect the function of their components, the fibrosa and the ventricularis. We have compared the elastic response of fibrosa and ventricularis fixed under 'low' and 'zero' tensile and compressive preload by testing 120 of these layers: (i) fresh, (ii) glutaraldehyde-fixed, and (iii) isolated from whole porcine aortic valve leaflets fixed while intact. In both the radial and circumferential directions, the fibrosa from intact-fixed valves was more extensible than the fresh (39.2 vs 29.2% strain to high modulus phase at p < 0.0122, and 12.7 vs 8.1% strain, at p < 0.0003, respectively). The ventricularis from intact-fixed valves, however, was less extensible than when fresh (35.4 vs 63.7% strain, at p < 0.00001 in the radial direction). The fibrosa must have, therefore, been fixed under compression and the ventricularis under tension, when fixed together in the intact aortic valve cusp. The tensile stresses in the intact-fixed ventricularis produced a greater circumferential elastic modulus than in separately fixed tissue (9.62 vs 4.65 MPa, at p < 0.00001), likely through a fibre recruitment process. Compressive stresses in the fibrosa produced a decrease in the elastic modulus both radially and circumferentially (from 3.79 to 2.26 MPa at p < 0.0023, and from 9.55 to 4.65 MPa at p < 0.00001, respectively). Fixing porcine aortic valves at even minimal tensile and compressive preload, such as that which occurs naturally, significantly alters both the extensibility and the elastic modulus of the valve leaflet components.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8429055     DOI: 10.1016/0021-9290(93)90043-e

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  13 in total

1.  One-dimensional experimental mechanical characterisation of porcine aortic root wall.

Authors:  C Ferraresi; A M Bertetto; L Mazza; D Maffiodo; W Franco
Journal:  Med Biol Eng Comput       Date:  1999-03       Impact factor: 2.602

Review 2.  Biological matrices and bionanotechnology.

Authors:  Patricia M Taylor
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2007-08-29       Impact factor: 6.237

3.  The use of thermal techniques for the characterization and selection of natural biomaterials.

Authors:  Valérie Samouillan; Florian Delaunay; Jany Dandurand; Nofel Merbahi; Jean-Pierre Gardou; Mohammed Yousfi; Alessandro Gandaglia; Michel Spina; Colette Lacabanne
Journal:  J Funct Biomater       Date:  2011-09-13

4.  A functionally graded material model for the transmural stress distribution of the aortic valve leaflet.

Authors:  Bruno V Rego; Michael S Sacks
Journal:  J Biomech       Date:  2017-02-08       Impact factor: 2.712

Review 5.  Mechanical considerations for polymeric heart valve development: Biomechanics, materials, design and manufacturing.

Authors:  Richard L Li; Jonathan Russ; Costas Paschalides; Giovanni Ferrari; Haim Waisman; Jeffrey W Kysar; David Kalfa
Journal:  Biomaterials       Date:  2019-09-17       Impact factor: 12.479

Review 6.  On the biomechanical function of scaffolds for engineering load-bearing soft tissues.

Authors:  John A Stella; Antonio D'Amore; William R Wagner; Michael S Sacks
Journal:  Acta Biomater       Date:  2010-01-07       Impact factor: 8.947

7.  Microstructure and Mechanical Property of Glutaraldehyde-Treated Porcine Pulmonary Ligament.

Authors:  Huan Chen; Xuefeng Zhao; Zachary C Berwick; Joshua F Krieger; Sean Chambers; Ghassan S Kassab
Journal:  J Biomech Eng       Date:  2016-06       Impact factor: 2.097

8.  A novel technique for quantifying mouse heart valve leaflet stiffness with atomic force microscopy.

Authors:  Mary-Kathryn Sewell-Loftin; Christopher B Brown; H Scott Baldwin; W David Merryman
Journal:  J Heart Valve Dis       Date:  2012-07

Review 9.  Application of hydrogels in heart valve tissue engineering.

Authors:  Xing Zhang; Bin Xu; Daniel S Puperi; Yan Wu; Jennifer L West; K Jane Grande-Allen
Journal:  J Long Term Eff Med Implants       Date:  2015

10.  An investigation of layer-specific tissue biomechanics of porcine atrioventricular valve anterior leaflets.

Authors:  Katherine E Kramer; Colton J Ross; Devin W Laurence; Anju R Babu; Yi Wu; Rheal A Towner; Arshid Mir; Harold M Burkhart; Gerhard A Holzapfel; Chung-Hao Lee
Journal:  Acta Biomater       Date:  2019-06-29       Impact factor: 8.947

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.