Reliability of a pulse oximeter in the detection of hyperoxemia.

C F Poets1, M Wilken, J Seidenberg, D P Southall, H von der Hardt.   

Abstract

To evaluate the reliability of the Nellcor N200 pulse oximeter in the detection of hyperoxemia (oxygen tension > 80 mm Hg), we obtained 213 simultaneous recordings and measurements of transcutaneous oxygen saturation (SO2) and arterial oxygen tension (PaO2) in 50 patients. During 95% of measurements with PaO2 > 80 mm Hg, SO2 was > or = 96%; SO2 was also > or = 96% in 20% of measurements with PaO2 < or = 80 mm Hg (false-positive results for hyperoxemia). With the upper alarm limit set at 95%, the pulse oximeter identified 95% of hyperoxemic instances while allowing PaO2 to be kept to > 60 mm Hg.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8419620     DOI: 10.1016/s0022-3476(05)83494-8

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  10 in total

1.  Individualised pulse oximetry limits in neonatal intensive care.

Authors:  R Gupta; C W Yoxall; N Subhedar; N J Shaw
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-11       Impact factor: 5.747

2.  The measurement of accurate fetal hemoglobin and related oxygen saturation by the hemoximeter.

Authors:  Shyang-Yun Pamela K Shiao; Ching-Nan Ou; Hector Pierantoni
Journal:  Clin Chim Acta       Date:  2006-06-06       Impact factor: 3.786

3.  Validation of oxygen saturation monitoring in neonates.

Authors:  Shyang-Yun Pamela K Shiao; Ching-Nan Ou
Journal:  Am J Crit Care       Date:  2007-03       Impact factor: 2.228

Review 4.  Intermittent Hypoxemia in Preterm Infants.

Authors:  Juliann M Di Fiore; Peter M MacFarlane; Richard J Martin
Journal:  Clin Perinatol       Date:  2019-06-15       Impact factor: 3.430

5.  Neonatal respiratory distress syndrome.

Authors:  D P Cochran; N J Shaw
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1994-05       Impact factor: 5.747

6.  Neonatal respiratory distress syndrome.

Authors:  D P Southall; M P Samuels; C F Poets
Journal:  Arch Dis Child       Date:  1993-09       Impact factor: 3.791

7.  Optimal oxygen saturation in premature infants.

Authors:  Meayoung Chang
Journal:  Korean J Pediatr       Date:  2011-09-30

8.  The use of pulse oximetry in the prevention of hyperoxaemia in preterm infants.

Authors:  D P Cochran; N J Shaw
Journal:  Eur J Pediatr       Date:  1995-03       Impact factor: 3.183

9.  Detection of hyperoxaemia in neonates: data from three new pulse oximeters.

Authors:  B Bohnhorst; C S Peter; C F Poets
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-11       Impact factor: 5.747

10.  Monitoring Oxygenation and Gas Exchange in Neonatal Intensive Care Units: Current Practice in the Netherlands.

Authors:  Ratna N G B Tan; Estelle E M Mulder; Enrico Lopriore; Arjan B Te Pas
Journal:  Front Pediatr       Date:  2015-11-03       Impact factor: 3.418

  10 in total