Literature DB >> 8419029

Fat-suppressed breath-hold magnetic resonance coronary angiography.

W J Manning1, W Li, N G Boyle, R R Edelman.   

Abstract

BACKGROUND: The ability to image the coronary arteries noninvasively would represent an advance in patient care. We have developed a magnetic resonance (MR) angiographic technique that allows the acquisition of complete images of coronary flow within a single breath-hold. By this method, the feasibility of noninvasive MR coronary angiography was evaluated in 25 subjects, including 19 healthy adult volunteers and six patients after diagnostic coronary angiography. METHODS AND
RESULTS: Noninvasive MR coronary angiography was performed with a fat-suppressed ECG-gated gradient-echo sequence with k-space segmentation. Overlapping transverse sections were initially used to image coronary flow, with oblique images obtained after identification of proximal anatomy. The left main coronary artery was seen in 24 subjects (96%), with a mean diameter of 4.8 mm (range, 3.4-6.2 mm) and average length of 10 mm (range, 8-14 mm). The left anterior descending coronary artery was seen in 100% of subjects, with a mean proximal diameter of 3.6 mm (range, 2.6-4.3 mm) and for an average length of 44 mm (range, 28-93 mm). The left circumflex coronary artery was seen in 76% of subjects, with a mean proximal diameter of 3.5 mm (range, 2.6-4.3 mm) and for an average length of 25 mm (range, 9-42 mm). The right coronary artery was also identified in 100% of subjects, with a mean proximal diameter of 3.7 mm (range, 2.7-5.1 mm) and for an average length of 58 mm (range, 24-122 mm). Quantitative angiography of normal proximal segments demonstrated a good correlation with MR-determined lumen diameters (r = 0.86, p < 0.002). Occluded vessels in patients with coronary artery disease displayed an absence of flow signal distal to the occlusion, whereas vessels with significant angiographic stenoses demonstrated signal loss corresponding to the area of the stenosis, with visualization of the more distal vessel.
CONCLUSIONS: Breath-hold MR coronary angiography provides visualization of the major epicardial vessels. In the future, MR coronary angiography may provide a noninvasive means for the evaluation of patients with known or suspected coronary artery disease.

Entities:  

Mesh:

Year:  1993        PMID: 8419029     DOI: 10.1161/01.cir.87.1.94

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  28 in total

1.  Magnetic resonance imaging of the coronary arteries: clinical results from three dimensional evaluation of a respiratory gated technique.

Authors:  R J van Geuns; H G de Bruin; B J Rensing; P A Wielopolski; M D Hulshoff; P M van Ooijen; M Oudkerk; P J de Feyter
Journal:  Heart       Date:  1999-10       Impact factor: 5.994

2.  Volume coronary angiography using targeted scans (VCATS): a new strategy in MR coronary angiography.

Authors:  R J van Geuns; P A Wielopolski; A J Wardeh; H G de Bruin; M Oudkerk; P J de Feyter
Journal:  Int J Cardiovasc Imaging       Date:  2001-10       Impact factor: 2.357

3.  3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography.

Authors:  M Hackenbroch; K Nehrke; J Gieseke; C Meyer; K Tiemann; H Litt; O Dewald; C P Naehle; H Schild; T Sommer
Journal:  Eur Radiol       Date:  2005-04-07       Impact factor: 5.315

4.  MR-based coronary artery blood velocity measurements in patients without coronary artery disease.

Authors:  M Schiemann; F Bakhtiary; V Hietschold; A Koch; A Esmaeili; H Ackermann; A Moritz; T J Vogl; N D Abolmaali
Journal:  Eur Radiol       Date:  2006-01-13       Impact factor: 5.315

5.  Potential quantitative magnetic resonance imaging biomarkers of coronary remodeling in older hypertensive patients.

Authors:  Kai Lin; Donald M Lloyd-Jones; Ying Liu; Xiaoming Bi; Debiao Li; James C Carr
Journal:  Arterioscler Thromb Vasc Biol       Date:  2012-04-26       Impact factor: 8.311

6.  Fast four-dimensional coronary MR angiography with k-t GRAPPA.

Authors:  Peng Lai; Feng Huang; Andrew C Larson; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2008-03       Impact factor: 4.813

Review 7.  Is aspirin safe for patients with heart failure?

Authors:  J G Cleland; C J Bulpitt; R H Falk; I N Findlay; C M Oakley; G Murray; P A Poole-Wilson; C R Prentice; G C Sutton
Journal:  Br Heart J       Date:  1995-09

8.  Two-dimensional coronary MRA: limitations and artifacts.

Authors:  A J Duerinckx; D P Atkinson; J Mintorovitch; O P Simonetti; M K Vrman
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

Review 9.  Glossary: methods for the measurement of coronary blood flow and myocardial perfusion.

Authors:  S G Sakka; D R Wallbridge; G Heusch
Journal:  Basic Res Cardiol       Date:  1996 Mar-Apr       Impact factor: 17.165

10.  Magnetic resonance imaging of coronary arteries: technique and preliminary results.

Authors:  D J Pennell; J Keegan; D N Firmin; P D Gatehouse; S R Underwood; D B Longmore
Journal:  Br Heart J       Date:  1993-10
View more