Literature DB >> 8418257

A procedure for patient repositioning and compensation for misalignment between transmission and emission data in PET heart studies.

V Bettinardi1, M C Gilardi, G Lucignani, C Landoni, G Rizzo, G Striano, F Fazio.   

Abstract

A procedure for patient repositioning and compensation for misalignment between transmission and emission data in positron emission tomography (PET) heart studies has been developed. Following the transmission scan (TR1), patients are moved from the scanner bed for the administration of the tracer, and repositioned when ready for the emission scan (EM1). A short postinjection transmission scan (TR2) is performed at the end of the EM1 study. TR1 and TR2 images are compared to recognize misalignment between transmission and emission studies. TR1 sinograms are compensated for misalignment to allow for a proper attenuation correction. The procedure has been tested on phantom and [18F]FDG PET heart studies. Misalignments down to 2.5 mm translation and 1 degree rotation in the transaxial plane and 4 mm in the axial direction can be recognized and compensated for. The procedure is suitable for clinical purposes, allowing reduction of patient time on the scanner bed, increased patient comfort and significant increase of patient throughput.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8418257

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  5 in total

1.  PET myocardial perfusion and glucose metabolism imaging: Part 2-Guidelines for interpretation and reporting.

Authors:  Heinrich R Schelbert; Robert Beanlands; Frank Bengel; Juhani Knuuti; Marcelo Dicarli; Josef Machac; Randolph Patterson
Journal:  J Nucl Cardiol       Date:  2003 Sep-Oct       Impact factor: 5.952

2.  Investigation of emission-transmission misalignment artifacts on rubidium-82 cardiac PET with adenosine pharmacologic stress.

Authors:  David M Schuster; Raghuveer K Halkar; Fabio P Esteves; Ernest V Garcia; C David Cooke; Mushabbar A Syed; F DuBois Bowman; John R Votaw
Journal:  Mol Imaging Biol       Date:  2008-05-03       Impact factor: 3.488

3.  A procedure for wall detection in [18F]FDG positron emission tomography heart studies.

Authors:  C Landoni; V Bettinardi; G Lucignani; M C Gilardi; G Striano; F Fazio
Journal:  Eur J Nucl Med       Date:  1996-01

4.  Reconstruction of rapidly acquired Germanium-68 transmission scans for cardiac PET attenuation correction.

Authors:  Bai-Ling Hsu; James A Case; Kevin W Moser; Timothy M Bateman; S James Cullom
Journal:  J Nucl Cardiol       Date:  2007 Sep-Oct       Impact factor: 5.952

5.  Positron emission tomography myocardial perfusion and glucose metabolism imaging.

Authors:  Josef Machac; Stephen L Bacharach; Timothy M Bateman; Jeroen J Bax; Robert Beanlands; Frank Bengel; Steven R Bergmann; Richard C Brunken; James Case; Dominique Delbeke; Marcelo F DiCarli; Ernest V Garcia; Richard A Goldstein; Robert J Gropler; Mark Travin; Randolph Patterson; Heinrich R Schelbert
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 3.872

  5 in total