Literature DB >> 8418025

Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.

B P Imholz1, G J Langewouters, G A van Montfrans, G Parati, J van Goudoever, K H Wesseling, W Wieling, G Mancia.   

Abstract

We tested Portapres, an innovative portable, battery-operated device for the continuous, noninvasive, 24-hour ambulatory measurement of blood pressure in the finger. Portapres is based on Finapres, a stationary device for the measurement of finger arterial pressure. Systems were added to record signals on tape, to alternate measurements between fingers automatically each 30 minutes, and to correct for the hydrostatic height of the hand. We compared the pressure as measured by Portapres with contralateral intrabrachial pressure measured with an Oxford device. Results were obtained in eight volunteers and 16 hypertensive patients. Time lost due to artifact was about 10% for each device. In two patients a full 24-hour Oxford profile was not obtained. In the remaining 22 subjects finger systolic, diastolic, and mean pressures differed +1 (SD 9), -8 (6), and -10 (6) mm Hg, respectively, from intrabrachial pressure. These diastolic and mean pressure underestimations are similar to what was found earlier for Finapres, are typical for the technique, and are systematic. Avoiding brisk hand movements resulted in fewer waveform artifacts. The hand had to be kept covered to continue recording at low outside temperatures. Sleep was not disturbed by Portapres, and arterial pressure showed a marked fall during siesta and nighttime. There were no major limitations in behavior, and no discomfort that originated from continuous monitoring was reported. Measurements continued normally during physical exercise. Portapres provides for the first time continuous 24-hour, noninvasive ambulatory blood pressure waveform monitoring and offers real and obvious advantages over current noninvasive and invasive devices.

Entities:  

Mesh:

Year:  1993        PMID: 8418025     DOI: 10.1161/01.hyp.21.1.65

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  41 in total

1.  A portable instrument for non-invasive monitoring of beat-by-beat cardiovascular haemodynamic parameters based on the volume-compensation and electrical-admittance method.

Authors:  M Nakagawara; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  2000-01       Impact factor: 2.602

2.  Continuous mean arterial pressure measurement in the fingers: the influence of local arm cooling.

Authors:  R Raamat; K Jagomägi; J Talts; E Länsimies; J Jurvelin; P Kolari
Journal:  Med Biol Eng Comput       Date:  2001-09       Impact factor: 2.602

3.  Sympathetic nervous system activity and cardiovascular homeostatis during head-up tilt in patients with spinal cord injuries.

Authors:  S Houtman; B Oeseburg; R L Hughson; M T Hopman
Journal:  Clin Auton Res       Date:  2000-08       Impact factor: 4.435

4.  Baroreflex failure following radiation therapy for nasopharyngeal carcinoma.

Authors:  H J Timmers; J M Karemaker; J W Lenders; W Wieling
Journal:  Clin Auton Res       Date:  1999-12       Impact factor: 4.435

Review 5.  Blood pressure variability: its measurement and significance in hypertension.

Authors:  Gianfranco Parati; Andrea Faini; Mariaconsuelo Valentini
Journal:  Curr Hypertens Rep       Date:  2006-06       Impact factor: 5.369

6.  Asymmetric time-dependent model for the dynamic finger arterial pressure-volume relationship.

Authors:  Jaak Talts; Rein Raamat; Kersti Jagomägi
Journal:  Med Biol Eng Comput       Date:  2006-08-03       Impact factor: 2.602

7.  Heart rate variability: why do spectral analysis?

Authors:  J M Karemaker
Journal:  Heart       Date:  1997-02       Impact factor: 5.994

8.  Low vagal tone is associated with impaired post stress recovery of cardiovascular, endocrine, and immune markers.

Authors:  Cora Stefanie Weber; Julian F Thayer; Miriam Rudat; Petra H Wirtz; Frank Zimmermann-Viehoff; Alexander Thomas; Frank H Perschel; Petra C Arck; Hans C Deter
Journal:  Eur J Appl Physiol       Date:  2010-01-07       Impact factor: 3.078

9.  Short-term postural reflexes in diabetic patients with autonomic dysfunction.

Authors:  Y Zhang; L A Critchley; Y H Tam; B Tomlinson
Journal:  Diabetologia       Date:  2003-12-03       Impact factor: 10.122

10.  Pathophysiological processes underlying emotional triggering of acute cardiac events.

Authors:  Philip C Strike; Kesson Magid; Daisy L Whitehead; Lena Brydon; Mimi R Bhattacharyya; Andrew Steptoe
Journal:  Proc Natl Acad Sci U S A       Date:  2006-03-02       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.