Literature DB >> 8415270

Dislocation following THA: comparison of two acetabular component designs.

W W Brien1, E A Salvati, T M Wright, A H Burstein.   

Abstract

One hundred ninety-seven consecutive primary cemented total hip arthroplasties using 22 mm heads were evaluated for the rate of dislocation. All surgery was performed by one surgeon through a posterior approach. A Charnley type femoral component was used in each case. Patients were divided into three groups based on the acetabular component used. Group I had 60 Charnley HPW cups implanted between January 1985 and December 1986; group II had 70 Tibac cups implanted between January 1987 and August 1987; and group III had 67 Charnley HPW cups implanted between September 1987 and February 1988. The groups were similar with regards to age, sex, original diagnosis, and surgical technique. There was a total of 11 dislocations (5.6%), of which 8 (11.4%) occurred in group II (Tibac cup). Furthermore, 6 patients (3%) developed recurrent hip dislocations, 5 (7.1%) of which were from group II. Group II had a statistically significant increase in the dislocation rate (P < .05). The authors conclude that the dislocation rate with the 22 mm Tibac cup is unacceptably high and that the design of the Charnley cup affords greater stability to the artificial hip joint than the hemispherical design of the Tibac cup.

Entities:  

Mesh:

Year:  1993        PMID: 8415270     DOI: 10.3928/0147-7447-19930801-04

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  5 in total

1.  Wear analysis of chamfered elongated acetabular cup liners.

Authors:  Hsiao-Che Lin; Tzuo-Liang Luo; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2011-12-22       Impact factor: 2.602

2.  Using nonlinear finite element models to analyse stress distribution during subluxation and torque required for dislocation of newly developed total hip structure after prosthetic impingement.

Authors:  Wei-Min Chi; Chien-Chung Lin; Ying-Jui Ho; Hsiao-Che Lin; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2017-07-01       Impact factor: 2.602

3.  Effects of design parameters of total hip components on the impingement angle and determination of the preferred liner skirt shape with an adequate oscillation angle.

Authors:  Hsiao-Che Lin; Wei-Min Chi; Ying-Jui Ho; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2012-11-29       Impact factor: 2.602

4.  Treatment of Recurrent Dislocation after Total Hip Arthroplasty Using Advanced Imaging and Three-Dimensional Modeling Techniques: A Case Series.

Authors:  Sean A Sutphen; Joseph D Lipman; Seth A Jerabek; David J Mayman; Christina I Esposito
Journal:  HSS J       Date:  2019-07-25

5.  Clinical validation of computer-assisted navigation in total hip arthroplasty.

Authors:  Eric Beaumont; Pierre Beaumont; Daniel Odermat; Isabelle Fontaine; Herbert Jansen; François Prince
Journal:  Adv Orthop       Date:  2010-11-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.