Image information transfer properties of x-ray intensifying screens in the energy range from 17 to 320 keV.

A Ginzburg1, C E Dick.   

Abstract

The image information transfer properties of a number of x-ray fluorescent screens have been measured for x-ray energies from 17 to 320 keV. The detective quantum efficiency of the screens at each x-ray energy has been determined by separate measurements of the x-ray absorption efficiency and the statistical factor associated with the emission of optical photons upon absorption of an incident x-ray. Data have been recorded for both rare-earth phosphor screens and calcium tungstate screens. The value of the statistical factor for optical photon emission tends toward a constant value as the incident energy increases. Comparisons of the image information transfer properties are presented for several screens, which have been measured over a ten year interval. The utility of the screens for high-energy radiography is discussed.

Entities:  

Mesh:

Year:  1993        PMID: 8413008     DOI: 10.1118/1.596998

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Comparison of CsI:Tl and Gd2 O2 S:Tb indirect flat panel detector x-ray imaging performance in front- and back-irradiation geometries.

Authors:  Adrian Howansky; Anastasiia Mishchenko; A R Lubinsky; Wei Zhao
Journal:  Med Phys       Date:  2019-09-23       Impact factor: 4.071

2.  Variance analysis of x-ray CT sinograms in the presence of electronic noise background.

Authors:  Jianhua Ma; Zhengrong Liang; Yi Fan; Yan Liu; Jing Huang; Wufan Chen; Hongbing Lu
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

3.  An apparatus and method for directly measuring the depth-dependent gain and spatial resolution of turbid scintillators.

Authors:  Adrian Howansky; A R Lubinsky; Katsuhiko Suzuki; S Ghose; Wei Zhao
Journal:  Med Phys       Date:  2018-10-01       Impact factor: 4.071

4.  Deriving depth-dependent light escape efficiency and optical Swank factor from measured pulse height spectra of scintillators.

Authors:  Adrian Howansky; Boyu Peng; Anthony R Lubinsky; Wei Zhao
Journal:  Med Phys       Date:  2017-02-13       Impact factor: 4.071

Review 5.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609