Literature DB >> 8406665

Bias and variability in blood pressure measurement with ambulatory recorders.

G Pannarale1, G Bebb, S Clark, A Sullivan, C Foster, A J Coats.   

Abstract

This study sought to determine whether patient characteristics such as age, sex, blood pressure, and pulse pressure differently affect the accuracy of an oscillometric (SpaceLabs 90207) and a microphonic (TM2420 version 7) blood pressure monitor. Blood pressure recorded by two oscillometric and two microphonic ambulatory monitors was compared with simultaneous readings by two pairs of trained, blinded observers using random-zero sphygmomanometry. One hundred and eighteen subjects (53 men and 65 women, aged 17 to 94 years; systolic pressure, 89 to 211 mm Hg; diastolic, 44 to 116 mm Hg) were studied. There were no significant differences within each observer pair or between the two observer pairs as well as no correlation between interobserver differences and patient characteristics. The differences between the monitor and trained observers' readings were 2.8 +/- 9.9 mm Hg systolic and 3.9 +/- 6.8 mm Hg diastolic for the SpaceLabs and 5.0 +/- 5.2 mm Hg systolic and 3.4 +/- 6.1 mm Hg diastolic for the TM2420. Patient characteristics that predicted measurement error were defined by multiple regression. For oscillometry, systolic measurement error was highly correlated with systolic pressure, pulse pressure, and subject age. The diastolic error was significantly correlated with pulse pressure, diastolic pressure, and subject sex. For the oscillometric monitor, patient characteristics accounted for 36.6% of the variation of the systolic error and 34.7% of the variation of the diastolic error. For the microphonic monitor, only age correlated with diastolic error, and no significant correlations were seen with systolic error. Patient characteristics accounted for only 1.2% of the systolic and 8.9% of the diastolic error.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8406665     DOI: 10.1161/01.hyp.22.4.591

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  7 in total

Review 1.  Ambulatory blood pressure monitoring in children and adolescents: coming of age?

Authors:  Empar Lurbe; María Isabel Torró; Julio Alvarez
Journal:  Curr Hypertens Rep       Date:  2013-06       Impact factor: 5.369

2.  The Healthy Core Metabolism: A New Paradigm for Primary Preventive Nutrition.

Authors:  A Fardet; E Rock
Journal:  J Nutr Health Aging       Date:  2016-03       Impact factor: 4.075

3.  Inter- and intraobserver reliability and validation of a new method for determination of eosinophil counts in patients with esophageal eosinophilia.

Authors:  Evan S Dellon; Karen J Fritchie; Tara C Rubinas; John T Woosley; Nicholas J Shaheen
Journal:  Dig Dis Sci       Date:  2009-10-15       Impact factor: 3.199

4.  Reliability of Oscillometric Blood Pressure Monitoring in Atrial Fibrillation Patients Admitted for Electric Cardioversion.

Authors:  Monica Maselli; Valter Giantin; Domenico Corrado; Alessandro Franchin; Francesca Attanasio; Valentina Pengo; Alessandra Tramontano; Pietro De Toni; Egle Perissinotto; Enzo Manzato
Journal:  J Clin Hypertens (Greenwich)       Date:  2015-04-09       Impact factor: 3.738

5.  Do we need to evaluate diastolic blood pressure in patients with suspected orthostatic hypotension?

Authors:  Artur Fedorowski; Viktor Hamrefors; Richard Sutton; J Gert van Dijk; Roy Freeman; Jacques Wm Lenders; Wouter Wieling
Journal:  Clin Auton Res       Date:  2017-02-27       Impact factor: 4.435

6.  Impact of measurement error on testing genetic association with quantitative traits.

Authors:  Jiemin Liao; Xiang Li; Tien-Yin Wong; Jie Jin Wang; Chiea Chuen Khor; E Shyong Tai; Tin Aung; Yik-Ying Teo; Ching-Yu Cheng
Journal:  PLoS One       Date:  2014-01-24       Impact factor: 3.240

7.  Comparison of morning vs bedtime administration of the combination of valsartan/amlodipine on nocturnal brachial and central blood pressure in patients with hypertension.

Authors:  Takeshi Fujiwara; Satoshi Hoshide; Yuichiro Yano; Hiroshi Kanegae; Kazuomi Kario
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-11-05       Impact factor: 3.738

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.